Advancing polarity-transcendent design: Development of a photoelectrochemical sensor with extended detection range
Biosensors and Bioelectronics · 2024-12 · 266 · 116736
DOI: 10.1016/j.bios.2024.116736 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-12. Verfasst von Zi-Long Ma und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Guangxi Minzu University, Key Laboratory of Chemistry and Engineering of Forest Products, State Ethnic …. Hauptthemen laut MEDLINE: Biosensing Techniques, Electrochemical Techniques, Copper, Limit of Detection. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 48 Literaturangaben.
Abstract (Originalsprache)
In photoelectrochemical (PEC) sensors, traditional detection modes such as "signal-on", "signal-off", and "polarity-switchable" limit target signals to a single polarity range, necessitating novel design strategies to enhance the operational scope. To overcome this limitation, we propose, for the first time, a "polarity-transcendent" design concept that enables a continuous response across the polarity spectrum, significantly broadening the sensor's concentration detection range. This concept is exemplified in our new "background-enhanced signal-off polarity-switchable" (BESOPS) mode, where the model analyte let-7a activates a cascade shearing reaction of a DNAzyme walker in conjunction with CRISPR/Cas12a, quantitatively peeling off Cu2O-H2 strands at the Cu2O/TiO2 electrode interface to expose the TiO2 surface. This exposure generates an anodic photocurrent at the expense of the cathodic photocurrent from Cu2O/TiO2, facilitating a seamless transition of the target signal from cathodic to anodic. Through systematic experiments and comparative analyses, the BESOPS sensor demonstrates highly sensitive and precise quantification of let-7a, with a detection limit of 2.5 aM and a broad operating range of 10 aM to 10 nM. Its performance exceeds most reported sensor platforms, highlighting the significant potential of our polarity-transcendent design in expanding the operational range of PEC sensors. This innovative approach paves the way for developing next-generation PEC sensors with enhanced applicability and heightened sensitivity in various critical fields.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Chemistry and Chemical Engineering, Guangxi Minzu University, Key Laboratory of Chemistry and Engineering of Forest Products, State Ethnic Affairs Commission, Guangxi Key Laboratory of Chemistry and Engineerin…
- Department of Pediatrics, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, 510080, China.
- School of Foreign Language, WuYi University, Jiangmen, 529100, China.
- Department of Pediatrics, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, 510080, China. Electronic address: tangylai@mail.sysu.edu.cn.
Zitieren
APA
Ma, Z. L., Song, S. Y., Sun, X. F., Xie, Y., Huang, L., Luo, H., Huang, K. J., Tan, X., & Tang, Y. L. (2024). Advancing polarity-transcendent design: Development of a photoelectrochemical sensor with extended detection range. Biosensors and Bioelectronics, 266, 116736. https://doi.org/10.1016/j.bios.2024.116736
Vancouver
Ma ZL, Song SY, Sun XF, Xie Y, Huang L, Luo H, et al. Advancing polarity-transcendent design: Development of a photoelectrochemical sensor with extended detection range. Biosensors and Bioelectronics. 2024;266:116736. doi:10.1016/j.bios.2024.116736
BibTeX
@article{Ma2024,
author = {Ma, Zi-Long and Song, Shi-Yao and Sun, Xu-Fei and Xie, Yi and Huang, Lei and Luo, Hu and Huang, Ke-Jing and Tan, Xuecai and Tang, Yan-Lai},
title = {Advancing polarity-transcendent design: Development of a photoelectrochemical sensor with extended detection range},
journal = {Biosensors and Bioelectronics},
year = {2024},
volume = {266},
pages = {116736},
doi = {10.1016/j.bios.2024.116736}
}
EUVIMED