EUVIMEDEUVIMED entdecken
Crossref

Single-atom-pair encoded photoelectrochemical sensing of tacrolimus in whole blood for monitoring-informed immunosuppression in organ transplantation

Haili Bao, Dan Li, Shiting Gu, Jing Huang, Hao Liu, Lei Zhang, Zhiren Fu, Xue Zhou, Dawei Xu, Zhonghai Zhang, Keyan Sun, Shaohua Song

Biosensors and Bioelectronics · 2026-11 · 311 · 118864

DOI: 10.1016/j.bios.2026.118864 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-11. Verfasst von Haili Bao und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Surgery, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, 200025, China. Hauptthemen laut MEDLINE: Tacrolimus, Biosensing Techniques, Immunosuppressive Agents, Drug Monitoring. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Therapeutic drug monitoring of tacrolimus (TAC) is essential for maintaining immune tolerance after organ transplantation, yet conventional assays often provide delayed and discontinuous measurements that constrain timely dose adjustment during periods of rapid pharmacokinetic fluctuation. Here we report a photoelectrochemical (PEC) TAC sensor that encodes molecular recognition at Ni1Cu2 single-atom pairs anchored on TiO2 photoelectrodes. Cooperative metal sites selectively engage TAC nitrogen and oxygen donors, enabling receptor-free recognition and controlled interfacial oxidation. An antifouling hydrogel interface suppresses nonspecific adsorption and preserves signal fidelity in protein- and cell-rich matrices, enabling minute-scale quantification at clinically relevant concentrations. The assay achieves an LOD of 0.1 ng mL-1 with a linear range of 0.5-20 ng mL-1 and maintains stability under biofouling challenge. In 120 transplant patient samples, PEC readouts agree with routine chemiluminescent immunoassay results across the therapeutic range. Finally, in rat liver and mouse heart transplantation models, monitoring-informed dosing adjustment improved survival compared with conventional dosing. By shortening the measurement-to-decision interval, this work provides a robust PEC sensing framework for TAC TDM in whole blood and supports more timely immunosuppressive management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TacrolimusBiosensing TechniquesImmunosuppressive AgentsDrug MonitoringAnimalsHumansElectrochemical TechniquesRatsMiceTitaniumHeart TransplantationCopperLimit of Detection

Stichwörter der Autor:innen

ImmunosuppressiveOrgan transplantationPhotoelectrochemicalSingle-atom pairTacrolimus

Substanzen

TacrolimusImmunosuppressive AgentsTitaniumtitanium dioxideCopper

Autor:innen und Institutionen

  • Department of General Surgery, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, 200025, China.
  • School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, 200241, China. Electronic address: shitinggu350@126.com.
  • School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, 200241, China.
  • School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, 200241, China. Electronic address: zhzhang@chem.ecnu.edu.cn.
  • Department of General Surgery, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, 200025, China. Electronic address: keyansun350@126.com.
  • Department of General Surgery, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, 200025, China. Electronic address: shaohuasong350@126.com.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Bao, H., Li, D., Gu, S., Huang, J., Liu, H., Zhang, L., Fu, Z., Zhou, X., Xu, D., Zhang, Z., Sun, K., & Song, S. (2026). Single-atom-pair encoded photoelectrochemical sensing of tacrolimus in whole blood for monitoring-informed immunosuppression in organ transplantation. Biosensors and Bioelectronics, 311, 118864. https://doi.org/10.1016/j.bios.2026.118864

Vancouver

Bao H, Li D, Gu S, Huang J, Liu H, Zhang L, et al. Single-atom-pair encoded photoelectrochemical sensing of tacrolimus in whole blood for monitoring-informed immunosuppression in organ transplantation. Biosensors and Bioelectronics. 2026;311:118864. doi:10.1016/j.bios.2026.118864

BibTeX
@article{Bao2026,
  author = {Bao, Haili and Li, Dan and Gu, Shiting and Huang, Jing and Liu, Hao and Zhang, Lei and Fu, Zhiren and Zhou, Xue and Xu, Dawei and Zhang, Zhonghai and Sun, Keyan and Song, Shaohua},
  title = {Single-atom-pair encoded photoelectrochemical sensing of tacrolimus in whole blood for monitoring-informed immunosuppression in organ transplantation},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {311},
  pages = {118864},
  doi = {10.1016/j.bios.2026.118864}
}
Kostenlos starten →