Target-Triggered Multiple-Polarity-Switchable Multiplexed Photoelectrochemical Platform
Analytical Chemistry · 2024
DOI: 10.1021/acs.analchem.4c02912 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2024. Verfasst von Zi-Long Ma und 7 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Chemistry and Engineering of Forest Products, State Ethnic Affairs Commission; Guangxi Key Laboratory of Chemistry and Engineering …. Hauptthemen laut MEDLINE: MicroRNAs, Electrochemical Techniques, Gold, Metal Nanoparticles. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: Specific Research Project of Guangxi for Research Bases and Talents, Natural Science Foundation of Guangxi Zhuang Autonomous Region, National Natural Science Foundation of China.
Abstract (Originalsprache)
Convenient and accurate quantification of disease-relevant multitargets is essential for community disease screening. However, in the field of photoelectrochemical (PEC) sensors for multisubstance detection, research on the continuous detection of multiple targets using a polarity-switching mode is scarce. In this study, a multiplexed PEC bioassay was developed based on a target-triggered "anodic-cathodic-anodic" multiple-polarity-switchable mode. Employing miRNA-21 and miRNA-141 as model analytes, the photosensitive material combinations of Cu2O/gold nanoparticles (AuNPs)/TiO2 and CdS/AuNPs/TiO2 were successively formed through the specific binding of different whisker branches of Whisker-DNA to Cu2O-H1 and the CdS-tripod DNA ring, respectively. This process reverses the photocurrent polarity from anodic to cathodic and then back to anodic upon detecting different targets, resulting in the high-sensitivity quantification of various biological targets with reduced interference. To enhance the device's utility and affordability in community disease screening, integrating a capacitor and a multimeter-smartphone connection simplifies the assembly and reduces costs. In developing the PEC sensor, the device demonstrated linear detection ranges for miRNA-21 and miRNA-141 from 0.01 fM to 10 nM. Detection limits for miRNA-21 and miRNA-141 were established at 3.2 and 4.3 aM, respectively. The innovative target-triggered multiple-polarity-switchable mode offers adaptability for other multitarget detections by simply modifying the structure of the whisker branches and the combination of photosensitive materials.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Chemistry and Engineering of Forest Products, State Ethnic Affairs Commission; Guangxi Key Laboratory of Chemistry and Engineering of Forest Products; Guangxi Collaborative Innovation Center for Chemis…
- Department of Pediatrics, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510080, China.
ORCID-Profile: Ke-Jing Huang
Förderung
- Specific Research Project of Guangxi for Research Bases and Talents
- Natural Science Foundation of Guangxi Zhuang Autonomous Region
- National Natural Science Foundation of China
- Foundation ability enhancement project of young teachers in Guangxi universities
Zitieren
APA
Ma, Z. L., Chen, J. J., Sun, X. F., Xie, Y., Luo, H., Huang, K. J., Tan, X., & Tang, Y. L. (2024). Target-Triggered Multiple-Polarity-Switchable Multiplexed Photoelectrochemical Platform. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c02912
Vancouver
Ma ZL, Chen JJ, Sun XF, Xie Y, Luo H, Huang KJ, et al. Target-Triggered Multiple-Polarity-Switchable Multiplexed Photoelectrochemical Platform. Analytical Chemistry. 2024. doi:10.1021/acs.analchem.4c02912
BibTeX
@article{Ma2024,
author = {Ma, Zi-Long and Chen, Jia-Jie and Sun, Xu-Fei and Xie, Yi and Luo, Hu and Huang, Ke-Jing and Tan, Xuecai and Tang, Yan-Lai},
title = {Target-Triggered Multiple-Polarity-Switchable Multiplexed Photoelectrochemical Platform},
journal = {Analytical Chemistry},
year = {2024},
doi = {10.1021/acs.analchem.4c02912}
}
EUVIMED