EUVIMEDEUVIMED entdecken
Crossref

Impedance-based polymer microneedle patch sensor for continuous interstitial fluid glucose monitoring

Honglin Piao, Yong-Ho Choi, Jaehyun Kim, Daerl Park, Jia Lee, Dahl-Young Khang, Heon-Jin Choi

Biosensors and Bioelectronics · 2024-03 · 247 · 115932

DOI: 10.1016/j.bios.2023.115932 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-03. Verfasst von Honglin Piao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Materials Science and Engineering, Yonsei University, Seoul, 03722, Republic of Korea. Hauptthemen laut MEDLINE: Blood Glucose Self-Monitoring, Biosensing Techniques. Die Arbeit wurde bisher 37-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Early detection and effective blood glucose control are critical for preventing and managing diabetes-related complications. Conventional glucometers provide point-in-time measurements but are painful and cannot facilitate continuous monitoring. Continuous glucose monitoring systems are comfortable but face challenges in terms of accuracy, cost, and sensor lifespan. This study aimed to develop a microneedle-based sensor patch for minimally invasive, painless, and continuous glucose monitoring in the interstitial fluid to address these limitations. Experimental results confirm painless and minimally invasive penetration of the skin tissue with cylindrical microneedles (3 × 3 array) to a depth of approximately 520 μm with minimal loading. The microneedle sensors fabricated with precision using the complementary metal-oxide semiconductor process were immobilized with glucose oxidase, as confirmed through phase angle analysis. Long-term tests confirmed the effective operation of the sensor for up to seven days. Glucose concentrations determined from the fitted concentration-impedance curves correlated well with those measured using commercial glucometers, indicating the reliability and precision of the microneedle sensor. The flexible and minimally invasive sensor developed in this study facilitates painless and continuous glucose monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Glucose Self-MonitoringBiosensing TechniquesBlood GlucosePolymersExtracellular FluidElectric ImpedanceReproducibility of ResultsNeedlesGlucose

Stichwörter der Autor:innen

Continuous monitoringDiabetesGlucometerImpedanceMicroneedlePenetration depth

Substanzen

Blood GlucosePolymersGlucose

Autor:innen und Institutionen

  • Department of Materials Science and Engineering, Yonsei University, Seoul, 03722, Republic of Korea.
  • Department of Materials Science and Engineering, Yonsei University, Seoul, 03722, Republic of Korea. Electronic address: dykhang@yonsei.ac.kr.
  • Department of Materials Science and Engineering, Yonsei University, Seoul, 03722, Republic of Korea. Electronic address: hjc@yonsei.ac.kr.

Zitieren

APA

Piao, H., Choi, Y. H., Kim, J., Park, D., Lee, J., Khang, D. Y., & Choi, H. J. (2024). Impedance-based polymer microneedle patch sensor for continuous interstitial fluid glucose monitoring. Biosensors and Bioelectronics, 247, 115932. https://doi.org/10.1016/j.bios.2023.115932

Vancouver

Piao H, Choi YH, Kim J, Park D, Lee J, Khang DY, et al. Impedance-based polymer microneedle patch sensor for continuous interstitial fluid glucose monitoring. Biosensors and Bioelectronics. 2024;247:115932. doi:10.1016/j.bios.2023.115932

BibTeX
@article{Piao2024,
  author = {Piao, Honglin and Choi, Yong-Ho and Kim, Jaehyun and Park, Daerl and Lee, Jia and Khang, Dahl-Young and Choi, Heon-Jin},
  title = {Impedance-based polymer microneedle patch sensor for continuous interstitial fluid glucose monitoring},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {247},
  pages = {115932},
  doi = {10.1016/j.bios.2023.115932}
}
Kostenlos starten →