Effect of interstitial fluid pH on transdermal glucose extraction by reverse iontophoresis
Biosensors and Bioelectronics · 2023-09 · 235 · 115406
DOI: 10.1016/j.bios.2023.115406 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-09. Verfasst von Wangwang Zhu und 8 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, 300072, China; Tianjin Key Laboratory of Biomedi…. Hauptthemen laut MEDLINE: Glucose, Biosensing Techniques. Die Arbeit wurde bisher 50-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Higher Education Discipline Innovation Project, National Natural Science Foundation of China.
Abstract (Originalsprache)
Reverse iontophoresis (RI) is a promising technology in the field of continuous glucose monitoring (CGM), offering significant advantages such as finger-stick-free operation, wearability, and non-invasiveness. In the glucose extraction process based on RI, the pH of the interstitial fluid (ISF) is a critical factor that needs further investigation, as it directly influences the accuracy of transdermal glucose monitoring. In this study, a theoretical analysis was conducted to investigate the mechanism by which pH affects the glucose extraction flux. Modeling and numerical simulations performed at different pH conditions indicated that the zeta potential was significantly impacted by the pH, thereby altering the direction and flux of the glucose iontophoretic extraction. A screen-printed glucose biosensor integrated with RI extraction electrodes was developed for ISF extraction and glucose monitoring. The accuracy and stability of the ISF extraction and glucose detection device were demonstrated with extraction experiments using different subdermal glucose concentrations ranging from 0 to 20 mM. The extraction results for different ISF pH values exhibited that at 5 mM and 10 mM subcutaneous glucose, the extracted glucose concentration was increased by 0.08212 mM and 0.14639 mM for every 1 pH unit increase, respectively. Furthermore, the normalized results for 5 mM and 10 mM glucose demonstrated a linear correlation, indicating considerable potential for incorporating a pH correction factor in the blood glucose prediction model used to calibrate glucose monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, 300072, China; Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin University, Tianjin,…
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin University, Tianjin, 300072, China.
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, 300072, China. Electronic address: puzhihua@tju.edu.cn.
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, 300072, China.
- Langzhong People's Hospital, Sichuan, 637499, China.
Förderung
- National Key Research and Development Program of China
- Higher Education Discipline Innovation Project
- National Natural Science Foundation of China
Zitieren
APA
Zhu, W., Yu, H., Pu, Z., Guo, Z., Zheng, H., Li, C., Zhang, X., Li, J., & Li, D. (2023). Effect of interstitial fluid pH on transdermal glucose extraction by reverse iontophoresis. Biosensors and Bioelectronics, 235, 115406. https://doi.org/10.1016/j.bios.2023.115406
Vancouver
Zhu W, Yu H, Pu Z, Guo Z, Zheng H, Li C, et al. Effect of interstitial fluid pH on transdermal glucose extraction by reverse iontophoresis. Biosensors and Bioelectronics. 2023;235:115406. doi:10.1016/j.bios.2023.115406
BibTeX
@article{Zhu2023,
author = {Zhu, Wangwang and Yu, Haixia and Pu, Zhihua and Guo, Zijing and Zheng, Hao and Li, Chengcheng and Zhang, Xingguo and Li, Jun and Li, Dachao},
title = {Effect of interstitial fluid pH on transdermal glucose extraction by reverse iontophoresis},
journal = {Biosensors and Bioelectronics},
year = {2023},
volume = {235},
pages = {115406},
doi = {10.1016/j.bios.2023.115406}
}
EUVIMED