Cartridge voltage-sensitive micropump immunosensor based on a self-assembled polydopamine coating mediated signal amplification strategy
Biosensors and Bioelectronics · 2023-04 · 226 · 115087
DOI: 10.1016/j.bios.2023.115087 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-04. Verfasst von Peng Lu und 9 weiteren Autor:innen. Beteiligte Einrichtung: College of Engineering, Huazhong Agricultural University, Wuhan, 430070, Hubei, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Metal Nanoparticles. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 39 Literaturangaben.
Abstract (Originalsprache)
Current biosensing detection assays were developed to focus on rapid, low-cost, stable detection for clinical diagnosis and food safety monitoring. In this work, a novel portable cartridge voltage-sensitive micropump immunosensor (CVMS) biosensing device based on the integration of the microchannel circuit biosensing principle and polydopamine (PDA) was presented for rapid and sensitive detection of pathogenic factors in real samples at trace levels. The CVMS can sensitively evaluate voltage signal changes caused by clogging effects in the closed-loop circuit when the insulated microspheres pass through the microchannel. The targets could trigger the immune reaction between antibody-antigens that leads to the change in the concentration of horseradish peroxidase (HRP). And the HRP was further employed to catalyze the polymerization of dopamine into PDA, resulting in the rapid formation of the magnetic @PDA nanoparticles (MNP@PDA) with core-shell structures. The abundant functional groups on the MNP@PDA surface can efficiently adsorb polystyrene microspheres, thus causing changes in the number of polystyrene microspheres (PS). The CVMS can accurately monitor the change of PS with a portable device, which weighs less than 0.8 kg and costs only $50. The completion of CVMS takes 90 min to complete. The limit of detection of this immunosensor for procalcitonin and ochratoxin A were 42 pg/mL and 77 pg/mL, respectively, which improved about 15 folds and 38 folds, respectively, than those of enzyme-linked immunosorbent assay.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Engineering, Huazhong Agricultural University, Wuhan, 430070, Hubei, China.
- College of Food Science and Technology, Huazhong Agricultural University, Wuhan, 430070, Hubei, China.
- Daye Public Inspection and Test Center, Daye, 435100, Hubei, China.
- College of Food Science and Technology, Huazhong Agricultural University, Wuhan, 430070, Hubei, China; Daye Public Inspection and Test Center, Daye, 435100, Hubei, China; Shenzhen Institute of Nutrition and Health, Huaz…
Zitieren
APA
Lu, P., Zhan, C., Huang, C., Zhou, Y., Hong, F., Wang, Z., Dong, Y., Li, N., He, Q., & Chen, Y. (2023). Cartridge voltage-sensitive micropump immunosensor based on a self-assembled polydopamine coating mediated signal amplification strategy. Biosensors and Bioelectronics, 226, 115087. https://doi.org/10.1016/j.bios.2023.115087
Vancouver
Lu P, Zhan C, Huang C, Zhou Y, Hong F, Wang Z, et al. Cartridge voltage-sensitive micropump immunosensor based on a self-assembled polydopamine coating mediated signal amplification strategy. Biosensors and Bioelectronics. 2023;226:115087. doi:10.1016/j.bios.2023.115087
BibTeX
@article{Lu2023,
author = {Lu, Peng and Zhan, Chen and Huang, Chenxi and Zhou, Yang and Hong, Feng and Wang, Zhilong and Dong, Yongzhen and Li, Nan and He, Qifu and Chen, Yiping},
title = {Cartridge voltage-sensitive micropump immunosensor based on a self-assembled polydopamine coating mediated signal amplification strategy},
journal = {Biosensors and Bioelectronics},
year = {2023},
volume = {226},
pages = {115087},
doi = {10.1016/j.bios.2023.115087}
}