EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Hierarchical Au@Pt nanoparticle/amino benzoic acid polymer-based hybrid material for labeled and label-free detection of interleukin-6: a comparative assessment

Dayana Soto, Verónica Serafín, María Pedrero, José M Pingarrón, Susana Campuzano, Jahir Orozco

Microchimica Acta · 2024

DOI: 10.1007/s00604-024-06745-y ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Microchimica Acta, 2024. Verfasst von Dayana Soto und 5 weiteren Autor:innen. Beteiligte Einrichtung: Max Planck Tandem Group in Nanobioengieneering, University of Antioquia, Complejo Ruta N, Calle 67 Nº 52-20, 050010, Medellín, Colombia. Hauptthemen laut MEDLINE: Interleukin-6, Gold, Metal Nanoparticles, Electrochemical Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: MCIN/AEI/10.13039/501100011033, ERDF A way of making Europe, Ministerio de Ciencia, Tecnología e Innovación.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Interleukin-6 (IL6) is a cytokine mainly involved in inflammatory processes associated with various diseases, from rheumatoid arthritis and pathogen-caused infections to cancer, where malignant cells exhibit high proliferation and overexpression of cytokines, including IL6. Furthermore, IL6 plays a fundamental role in detecting and differentiating tumor cells, including colorectal cancer (CRC) cells. Therefore, given its range of biological activities and pathological role, IL6 determination has been claimed for the diagnosis/prognosis of immune-mediated diseases. Herein, a comparative study is presented of labeled and label-free electrochemical immunosensors involving a hierarchical Au@Pt nanoparticle/polymer hybrid material for detecting IL6. The electrochemical immunosensors were independently coupled to the surface of screen-printed carbon electrodes (SPCEs) previously modified with polymeric layers. While in the label-free immunosensor, an anti-IL6 antibody (IL6-Ab) was covalently bound to the modified SPCE surface, in the sandwich-like amperometric immunosensor, an anti-biotinylated-IL6 antibody (B-IL6-Ab) was attached to the electrode through biotin-avidin affinity interactions. The label-free format employed a straightforward detection of IL6 by differential pulse voltammetry (DPV). The resulting electrochemical immunosensors exhibited a linear dynamic range from 50 to 750 pg/mL IL6, with detection limits (LOD) of 14.4 and 6.0 pg/mL for label-free and sandwich-like immunosensors, respectively. This outstanding performance makes them versatile platforms for clinical analysis of a panel of biomarkers for early diagnosis/prognosis of inflammatory processes associated with oncological diseases, among other pathologies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Interleukin-6GoldMetal NanoparticlesElectrochemical TechniquesPolymersHumansImmunoassayPlatinumBiosensing TechniquesLimit of DetectionAntibodies, ImmobilizedElectrodes

Stichwörter der Autor:innen

Differential pulse voltammetryElectrochemical detectionGold nanoparticlesHybrid nanomaterialLabel-free immunosensorMulti-walled carbon nanotubesSandwich-like immunosensorScreen-printed carbon electrode

Substanzen

Interleukin-6GoldPolymersPlatinumAntibodies, ImmobilizedIL6 protein, human

Autor:innen und Institutionen

  • Max Planck Tandem Group in Nanobioengieneering, University of Antioquia, Complejo Ruta N, Calle 67 Nº 52-20, 050010, Medellín, Colombia.
  • CECOLTEC Group, Cecoltec Services S.A.S Company, Universidad EAFIT, Edificio Ingenierías, Bloque 19, 050022, Medellín, Colombia.
  • Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, Pza. de Las Ciencias 2, 28040, Madrid, Spain.
  • Max Planck Tandem Group in Nanobioengieneering, University of Antioquia, Complejo Ruta N, Calle 67 Nº 52-20, 050010, Medellín, Colombia. grupo.tandemnanobioe@udea.edu.co.

Förderung

  • MCIN/AEI/10.13039/501100011033
  • ERDF A way of making Europe
  • Ministerio de Ciencia, Tecnología e Innovación
  • Enlaza Mundos

Zitieren

APA

Soto, D., Serafín, V., Pedrero, M., Pingarrón, J. M., Campuzano, S., & Orozco, J. (2024). Hierarchical Au@Pt nanoparticle/amino benzoic acid polymer-based hybrid material for labeled and label-free detection of interleukin-6: a comparative assessment. Microchimica Acta. https://doi.org/10.1007/s00604-024-06745-y

Vancouver

Soto D, Serafín V, Pedrero M, Pingarrón JM, Campuzano S, Orozco J. Hierarchical Au@Pt nanoparticle/amino benzoic acid polymer-based hybrid material for labeled and label-free detection of interleukin-6: a comparative assessment. Microchimica Acta. 2024. doi:10.1007/s00604-024-06745-y

BibTeX
@article{Soto2024,
  author = {Soto, Dayana and Serafín, Verónica and Pedrero, María and Pingarrón, José M and Campuzano, Susana and Orozco, Jahir},
  title = {Hierarchical Au@Pt nanoparticle/amino benzoic acid polymer-based hybrid material for labeled and label-free detection of interleukin-6: a comparative assessment},
  journal = {Microchimica Acta},
  year = {2024},
  doi = {10.1007/s00604-024-06745-y}
}
Kostenlos starten →