EUVIMEDEUVIMED entdecken
Crossref

Energy level-engineered of PS@PANI/AuNPs core-shell nanoprobes for magazine-type quasi-solid-state ECL immunosensing of AFP

Haoyi Ren, WenWen Jiang, Zhina Li, Yige Li, Baohan Wen, MingZhe Jiang, Hongling Li, Chenglin Hong

Analytica Chimica Acta · 2026-09 · 1413 · 345657

DOI: 10.1016/j.aca.2026.345657 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-09. Verfasst von Haoyi Ren und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering/State Key Laboratory Incubation Base for Green Processing of Chemical Engineering, Shihezi University, S…. Hauptthemen laut MEDLINE: alpha-Fetoproteins, Metal Nanoparticles, Gold, Aniline Compounds. Die Arbeit nennt 27 Literaturangaben. Gefördert von: Shihezi University, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Early cancer screening in resource-limited settings demands low-cost, high-performance sensors, where nanomaterial design is critical to breaking the limitations of traditional electrode-based platforms. Herein, we report a magazine-type quasi-solid-state electrochemiluminescence (ECL) immunosensor for sensitive detection of alpha-fetoprotein (AFP, a hepatocellular carcinoma marker), enabled by energy level-engineered PS@PANI/AuNPs core-shell nanoprobes and a 3D-printed continuous detection device. 350 nm polystyrene (PS) nanoparticles serve as templates to synthesize PS@PANI/AuNPs (with 12 nm AuNPs uniformly distributed on the PANI shell). Orthogonal experiments were employed to precisely regulate the oxidation state (phenylenediamine/quinonediimine ratio) and doping state (sulfosalicylic acid) of PANI, achieving matched HOMO/LUMO energy levels between PANI and the excited state of Ru(bpy)32+. The sensor uses agarose gel as a quasi-solid substrate: glutaraldehyde activation enables efficient immobilization of capture antibodies, providing a biocompatible, low-cost biointerface. Integration of the gel substrate with a 3D-printed magazine-type device enables sequential analysis of up to 20 samples per hour. Under optimal conditions, the sensor exhibits a linear range of 0.39-200 ng/mL, a limit of detection (LOD) of 0.28 ng/mL, and excellent stability (RSD = 2.87%). This work highlights the role of nanomaterial electronic structure regulation in advancing ECL sensors, offering a scalable, low-cost solution for early cancer screening in global health applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

alpha-FetoproteinsMetal NanoparticlesGoldAniline CompoundsElectrochemical TechniquesPolystyrenesBiosensing TechniquesImmunoassayHumansLuminescent MeasurementsLimit of Detection

Stichwörter der Autor:innen

Doping stateElectrochemiluminescenceOxidation statePolyanilineQuasi-solid-state

Substanzen

alpha-FetoproteinsGoldAniline CompoundsPolystyrenespolyaniline

Autor:innen und Institutionen

  • School of Chemistry and Chemical Engineering/State Key Laboratory Incubation Base for Green Processing of Chemical Engineering, Shihezi University, Shihezi, 832003, PR China.
  • School of Chemistry and Chemical Engineering/State Key Laboratory Incubation Base for Green Processing of Chemical Engineering, Shihezi University, Shihezi, 832003, PR China. Electronic address: jiangmingzhe@shzu.edu.cn.
  • School of Chemistry and Chemical Engineering/State Key Laboratory Incubation Base for Green Processing of Chemical Engineering, Shihezi University, Shihezi, 832003, PR China. Electronic address: lhl_tea@shzu.edu.cn.
  • School of Chemistry and Chemical Engineering/State Key Laboratory Incubation Base for Green Processing of Chemical Engineering, Shihezi University, Shihezi, 832003, PR China. Electronic address: hcl_tea@shzu.edu.cn.

Förderung

  • Shihezi University
  • National Natural Science Foundation of China

Zitieren

APA

Ren, H., Jiang, W., Li, Z., Li, Y., Wen, B., Jiang, M., Li, H., & Hong, C. (2026). Energy level-engineered of PS@PANI/AuNPs core-shell nanoprobes for magazine-type quasi-solid-state ECL immunosensing of AFP. Analytica Chimica Acta, 1413, 345657. https://doi.org/10.1016/j.aca.2026.345657

Vancouver

Ren H, Jiang W, Li Z, Li Y, Wen B, Jiang M, et al. Energy level-engineered of PS@PANI/AuNPs core-shell nanoprobes for magazine-type quasi-solid-state ECL immunosensing of AFP. Analytica Chimica Acta. 2026;1413:345657. doi:10.1016/j.aca.2026.345657

BibTeX
@article{Ren2026,
  author = {Ren, Haoyi and Jiang, WenWen and Li, Zhina and Li, Yige and Wen, Baohan and Jiang, MingZhe and Li, Hongling and Hong, Chenglin},
  title = {Energy level-engineered of PS@PANI/AuNPs core-shell nanoprobes for magazine-type quasi-solid-state ECL immunosensing of AFP},
  journal = {Analytica Chimica Acta},
  year = {2026},
  volume = {1413},
  pages = {345657},
  doi = {10.1016/j.aca.2026.345657}
}
Kostenlos starten →