EUVIMEDEUVIMED entdecken
Crossref

The AAHKS Clinical Research Award: Maximizing Bearing Size Markedly Reduces Dislocations in Primary Total Hip Arthroplasty

Eric Wang, Kyle McCormick, Catherine Di Gangi, Theodor Di Pauli von Treuheim, Morteza Meftah, Ran Schwarzkopf, Matthew S Hepinstall

The Journal of Arthroplasty · 2026

DOI: 10.1016/j.arth.2026.06.028 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2026. Verfasst von Eric Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, NYU Langone Health, New-York, New York. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Prosthesis Design, Hip Dislocation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Modern polyethylene allows larger bearings in fixed-bearing total hip arthroplasty (THA), but any stability benefits of fully maximizing bearing diameter (e.g., 36-millimeter (mm) in 48/50-mm cups) are not well-established. We hypothesized that maximizing bearing diameter reduces odds of dislocation in primary fixed-bearing THA. METHODS: We retrospectively reviewed all patients who underwent fixed-bearing THA at a large, urban, academic institution between 2016 and 2022. We noted cases receiving the largest bearing available from any manufacturer for the acetabular diameter: 28 mm in 40/42 mm, 32 mm in 44/46-, 36- in 48/50-, or 40- in 52/54/56 mm. Larger cups were excluded because proportionately larger bearings were unavailable. Multivariate analyses using least-absolute-shrinkage-and-selection-operator logistic regression were performed to explore the association between maximized bearing diameter and dislocation risk while controlling for confounders. RESULTS: Bearing diameter was maximized in 835 (9.8%) of 8,607 patients, whereas 7,309 (84.9%) received the second-largest bearing available. There were 79 dislocations (0.9% overall); none occurred with maximized bearing diameters (P = 0.003). On univariate analyses, dislocation risk also varied with intraoperative technology use, surgical approach, and liner geometry (P = 0.017, P = 0.008, P = 0.007, respectively). In least-absolute-shrinkage-and-selection-operator regression including these variables, maximized bearing diameters heavily protected against dislocation (odds ratio (OR) = 0.14). Robotic surgery (OR = 0.35), computer-navigation (OR = 0.90), lateral (OR = 0.48), and anterior (OR = 0.62) approaches were also protective. Lipped (OR = 1.2) and offset (OR = 1.4) liners, commonly used with posterior approaches and nonmaximized bearing diameters, were associated with slightly higher odds of dislocation. Subanalysis of 4,185 patients who underwent posterior approach THA using nonmaximized bearings revealed that liner geometry did not impact dislocation odds within this subgroup. CONCLUSIONS: Fully maximizing bearing diameter markedly reduced dislocation odds in primary fixed-bearing THA. The magnitude of this effect was substantially larger compared to other variables under surgeon control.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisProsthesis DesignHip DislocationHumansRetrospective StudiesAwards and PrizesFemaleMaleAgedMiddle AgedProsthesis FailurePolyethylene

Stichwörter der Autor:innen

dislocationsfixed-bearinginstabilitymaximized bearingtotal hip arthroplasty

Substanzen

Polyethylene

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, NYU Langone Health, New-York, New York.

Zitieren

APA

Wang, E., McCormick, K., Di Gangi, C., Di Pauli von Treuheim, T., Meftah, M., Schwarzkopf, R., & Hepinstall, M. S. (2026). The AAHKS Clinical Research Award: Maximizing Bearing Size Markedly Reduces Dislocations in Primary Total Hip Arthroplasty. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2026.06.028

Vancouver

Wang E, McCormick K, Di Gangi C, Di Pauli von Treuheim T, Meftah M, Schwarzkopf R, et al. The AAHKS Clinical Research Award: Maximizing Bearing Size Markedly Reduces Dislocations in Primary Total Hip Arthroplasty. The Journal of Arthroplasty. 2026. doi:10.1016/j.arth.2026.06.028

BibTeX
@article{Wang2026,
  author = {Wang, Eric and McCormick, Kyle and Di Gangi, Catherine and Di Pauli von Treuheim, Theodor and Meftah, Morteza and Schwarzkopf, Ran and Hepinstall, Matthew S},
  title = {The AAHKS Clinical Research Award: Maximizing Bearing Size Markedly Reduces Dislocations in Primary Total Hip Arthroplasty},
  journal = {The Journal of Arthroplasty},
  year = {2026},
  doi = {10.1016/j.arth.2026.06.028}
}
Kostenlos starten →