Large Femoral Heads and Select Dual-Mobility Bearings Are Associated With Reduced Instability in Contemporary Posterior Approach Total Hip Arthroplasty
The Journal of Arthroplasty · 2023
DOI: 10.1016/j.arth.2023.02.011 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2023. Verfasst von Lauren I Pitz-Gonçalves und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery and Rehabilitation Services, The University of Chicago, Chicago, Illinois. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Joint Dislocations, Hip Dislocation. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 73 Literaturangaben. Gefördert von: American Association of Hip and Knee Surgeons.
Themen: Mobilisation
Abstract (Originalsprache)
BACKGROUND: Postoperative dislocation is considered the main drawback of posterior approach total hip arthroplasty (THA). Thinner highly cross-linked polyethylene and dual-mobility bearings allow maximizing femoral head diameter per a given cup size. This study evaluated dislocation rates as large femoral head bearings were introduced into a practice over an 11-year period. METHODS: A total of 1,511 consecutive primary THAs were retrospectively reviewed. Demographics, implant sizes, femoral head-acetabular cup ratio, and dislocation status were collected from the electronic medical record. Data were evaluated using time series analysis techniques as larger femoral heads, thinner polyethylene liners, and dual-mobility bearings were introduced. The cohort was 57% women with mean age and body mass index of 62 years (range, 13 to 93) and 31 kg/m2 (range, 13 to 54), respectively. RESULTS: The overall dislocation rate was 0.98%. Use of femoral head sizes ≥ 40 millimeters increased from 4% in the years 2010 to 2016 to 51% in the years 2017 to 2021, correlating with a 50% reduction in dislocation rate from 1.4% to 0.7% (P = .279). Also, no dislocations occurred in patients who had dual-mobility bearings or ≥ 40-millimeter femoral heads (P = .007). Twelve of 14 dislocations occurred in cases with head-cup ratio < 0.7 (P = .013). Thirteen of 14 dislocations were in women (P = .005). CONCLUSION: Maximizing the femoral head diameter per given cup size correlated with a decrease in dislocation rate in modern posterior approach THA. Furthermore, these results suggest that dual-mobility articulations should be reserved for high-risk patients or patients in whom a 40-millimeter femoral head is not possible. LEVEL OF EVIDENCE: IV-consecutive case series; no control group.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery and Rehabilitation Services, The University of Chicago, Chicago, Illinois.
- Indiana Joint Replacement Institute, Indianapolis, Indiana.
- Indiana Joint Replacement Institute, Indianapolis, Indiana; Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, Indiana.
Förderung
- American Association of Hip and Knee Surgeons
Zitieren
APA
Pitz-Gonçalves, L. I., Deckard, E. R., & Meneghini, R. M. (2023). Large Femoral Heads and Select Dual-Mobility Bearings Are Associated With Reduced Instability in Contemporary Posterior Approach Total Hip Arthroplasty. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2023.02.011
Vancouver
Pitz-Gonçalves LI, Deckard ER, Meneghini RM. Large Femoral Heads and Select Dual-Mobility Bearings Are Associated With Reduced Instability in Contemporary Posterior Approach Total Hip Arthroplasty. The Journal of Arthroplasty. 2023. doi:10.1016/j.arth.2023.02.011
BibTeX
@article{PitzGonalves2023,
author = {Pitz-Gonçalves, Lauren I and Deckard, Evan R and Meneghini, R Michael},
title = {Large Femoral Heads and Select Dual-Mobility Bearings Are Associated With Reduced Instability in Contemporary Posterior Approach Total Hip Arthroplasty},
journal = {The Journal of Arthroplasty},
year = {2023},
doi = {10.1016/j.arth.2023.02.011}
}
EUVIMED