EUVIMEDEUVIMED entdecken
Crossref

How Effective Are Constrained Liners at Preventing Dislocation After Revision Total Hip Arthroplasty?

Sharrieff N Shah, Justin Leal, Matthew K Stein, David G Deckey, Andrew M Schwartz, Michael P Bolognesi, Sean P Ryan

The Journal of Arthroplasty · 2026

DOI: 10.1016/j.arth.2026.01.012 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2026. Verfasst von Sharrieff N Shah und 6 weiteren Autor:innen. Beteiligte Einrichtung: Duke University School of Medicine, Duke University, Durham, North Carolina. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Hip Dislocation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Recurrent instability continues to challenge arthroplasty surgeons, and constrained liners may be utilized for cases of recurrent or multidirectional instability following revision total hip arthroplasty (rTHA). The purpose of this study was to evaluate dislocation rates and survivorship after rTHA using constrained liner (CL) prostheses. METHODS: Patients who underwent rTHA using a CL prosthesis were retrospectively reviewed from January 1, 2013, to December 31, 2024. Patients who had antibiotic spacers or megaprostheses, or those who had less than one year of follow-up, were excluded. Survivorship analyses were performed to determine dislocation and reoperation-free survivorship through follow-up. A total of 98 rTHAs with CL were included, with a mean follow-up time of 3.9 years (range, one to 10.8). RESULTS: The CL dislocation rate at final follow-up was 16.3% (16 of 98), and the 9-year dislocation-free survivorship was 71% (95% confidence interval [57 to 89]). There was neither statistically significant difference in 9-year dislocation-free survivorship among CL systems (P = 0.73), CLs inserted into cups that were retained versus revised (P = 0.95), nor CLs that were snapped in versus cemented (P = 0.38). The overall reoperation rate at final follow-up was 49.0% (48 of 98), and the 9-year all-cause reoperation-free survivorship was 33% (95% confidence interval [17 to 62%]). Of those 48 requiring reoperation, 27 (56.2%) were for infection and 14 (29.2%) were for recurrent hip instability. There was neither statistically significant difference in 9-year all-cause reoperation-free survivorship among CLs inserted into cups that were retained versus revised (P = 0.67) nor CLs that were snapped in versus cemented (P = 0.34). CONCLUSIONS: In a cohort where a majority of patients had multiple prior rTHAs secondary to hip instability, CLs were a salvage option for preventing repeat dislocation; however, dislocation and reoperation rates remain high. LEVEL OF EVIDENCE: Level III Evidence, Retrospective Cohort Study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisHip DislocationHumansReoperationRetrospective StudiesFemaleAgedProsthesis FailureMaleMiddle AgedProsthesis DesignJoint InstabilityAged, 80 and overFollow-Up StudiesAdult

Stichwörter der Autor:innen

constrained linerdislocationhip instabilityimplant survivorshiprevision total hip arthroplasty (rTHA)

Autor:innen und Institutionen

  • Duke University School of Medicine, Duke University, Durham, North Carolina.
  • Department of Orthopaedic Surgery, Duke University School of Medicine, Duke University, Durham, North Carolina.

Zitieren

APA

Shah, S. N., Leal, J., Stein, M. K., Deckey, D. G., Schwartz, A. M., Bolognesi, M. P., & Ryan, S. P. (2026). How Effective Are Constrained Liners at Preventing Dislocation After Revision Total Hip Arthroplasty?. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2026.01.012

Vancouver

Shah SN, Leal J, Stein MK, Deckey DG, Schwartz AM, Bolognesi MP, et al. How Effective Are Constrained Liners at Preventing Dislocation After Revision Total Hip Arthroplasty?. The Journal of Arthroplasty. 2026. doi:10.1016/j.arth.2026.01.012

BibTeX
@article{Shah2026,
  author = {Shah, Sharrieff N and Leal, Justin and Stein, Matthew K and Deckey, David G and Schwartz, Andrew M and Bolognesi, Michael P and Ryan, Sean P},
  title = {How Effective Are Constrained Liners at Preventing Dislocation After Revision Total Hip Arthroplasty?},
  journal = {The Journal of Arthroplasty},
  year = {2026},
  doi = {10.1016/j.arth.2026.01.012}
}
Kostenlos starten →