EUVIMEDEUVIMED entdecken
Crossref

Accuracy of Fluoroscopic Navigation for Predicting Leg Length and Offset in Primary Hip Arthroplasty

Michael P Murphy, Patrick J Kelly, John R Dunn, Grant D Hamilton, Addison E Clift, William G Hamilton

The Journal of Arthroplasty · 2026-09 · 41 (9) · S192-S196

DOI: 10.1016/j.arth.2026.04.110 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2026-09. Verfasst von Michael P Murphy und 5 weiteren Autor:innen. Beteiligte Einrichtung: Anderson Orthopaedic Research Institute Department of Orthopaedic Surgery, Alexandria, Virginia. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Surgery, Computer-Assisted, Leg Length Inequality. Die Arbeit nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND Fluoroscopic-assisted computer navigation is widely used to guide intraoperative decisions on leg length (LL) and offset in primary total hip arthroplasty (THA), but its accuracy remains under-evaluated. This study assessed the precision of a fluoroscopy-based navigation system by comparing its intraoperative predictions to validated postoperative measurements. METHODS We retrospectively reviewed 490 consecutive primary THA cases performed by three surgeons at a tertiary academic center. Intraoperative changes in LL and offset using a fluoroscopic navigation system were recorded. Pre- and postoperative antero-posterior pelvis radiographs were measured using an artificial intelligence (AI)-based algorithm to determine actual changes in LL and offset. Navigated and radiographic values were compared using mean/median differences and by percentage of cases within clinically relevant thresholds: ± three, ± five, and ± 10 mm. RESULTS For LL, postoperative AI-based measurements showed a mean change of 4.1 ± 5.6 mm (median 3.7), while the intraoperative navigation system predicted a mean change of 2.5 ± 3.1 mm (median 2, P < 0.0001). Navigation underestimated LL change on average. Predictions were within ± three mm in 65.8% of cases, ± five mm in 86.0%, and ± 10 mm in 98.5%. For femoral offset, AI-based measurements showed a mean postoperative change of 1.7 ± 5.4 mm (median 1.6), compared with a mean predicted change of 3.4 ± 5.0 mm (median 3) from navigation (P < 0.0001). Navigation overestimated offset change on average. Accuracy was within ± three mm in 44.1% of cases, ± five mm in 64.9%, and ± 10 mm in 93.9%. CONCLUSIONS Although the fluoroscopy-based navigation system showed statistically significant differences from postoperative radiographic measurements, it achieved clinically acceptable accuracy in most cases. These findings support the system's utility in guiding THA while emphasizing the importance of intraoperative awareness of its limitations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipSurgery, Computer-AssistedLeg Length InequalityHumansRetrospective StudiesFluoroscopyFemaleMaleMiddle AgedAgedArtificial IntelligenceAdultAged, 80 and overHip Joint

Stichwörter der Autor:innen

artificial intelligencefemoral offsetfluoroscopic navigationleg lengthtotal hip arthroplasty

Autor:innen und Institutionen

  • Anderson Orthopaedic Research Institute Department of Orthopaedic Surgery, Alexandria, Virginia.

Zitieren

APA

Murphy, M. P., Kelly, P. J., Dunn, J. R., Hamilton, G. D., Clift, A. E., & Hamilton, W. G. (2026). Accuracy of Fluoroscopic Navigation for Predicting Leg Length and Offset in Primary Hip Arthroplasty. The Journal of Arthroplasty, 41(9), S192-S196. https://doi.org/10.1016/j.arth.2026.04.110

Vancouver

Murphy MP, Kelly PJ, Dunn JR, Hamilton GD, Clift AE, Hamilton WG. Accuracy of Fluoroscopic Navigation for Predicting Leg Length and Offset in Primary Hip Arthroplasty. The Journal of Arthroplasty. 2026;41(9):S192-S196. doi:10.1016/j.arth.2026.04.110

BibTeX
@article{Murphy2026,
  author = {Murphy, Michael P and Kelly, Patrick J and Dunn, John R and Hamilton, Grant D and Clift, Addison E and Hamilton, William G},
  title = {Accuracy of Fluoroscopic Navigation for Predicting Leg Length and Offset in Primary Hip Arthroplasty},
  journal = {The Journal of Arthroplasty},
  year = {2026},
  volume = {41},
  number = {9},
  pages = {S192--S196},
  doi = {10.1016/j.arth.2026.04.110}
}
Kostenlos starten →