Intraoperative computerised tomography scan for percutaneous fixation of the pelvis: a retrospective case series
International Orthopaedics · 2024
DOI: 10.1007/s00264-024-06265-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Orthopaedics, 2024. Verfasst von Monahan Kevin und 7 weiteren Autor:innen. Beteiligte Einrichtung: Allegheny General Hospital, 320 E North Ave, Pittsburgh, PA, 15201, USA. Hauptthemen laut MEDLINE: Pelvic Bones, Fractures, Bone, Tomography, X-Ray Computed, Fracture Fixation, Internal. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Fractures and dislocations of the pelvic ring are complex injuries that when treating require meticulous attention to detail and often specialized technical skill. These injuries can be the result of high-energy trauma, particularly in younger patients, or low energy trauma more often found in the elderly. Regardless of mechanism, these injuries lie on a spectrum of severity and can be treated conservatively or surgically. Percutaneous fixation under fluoroscopic guidance is the preferred standard technique when treating these fractures. This technique can be challenging for a variety of reasons including patient characteristics, intra-operative image quality, fracture morphology, among others.
Methods
This retrospective study evaluated the use of intra-operative computed tomography (CT) using an O-arm imaging system for critical evaluation of fluoroscopic-guided screw placement in twenty-three patients. We retrospectively reviewed all cases of patients who were treated by three fellowship-trained orthopaedic traumatologists during a one-year span. Patients undergoing percutaneous pelvis fixation using both standard fluoroscopy and intraoperative CT with the Medtronic O-arm® (Minneapolis, MN) imaging system. Additionally, procedures performed included open reduction internal fixation (ORIF) of the pelvic ring, acetabulum, and associated extremity fractures.
Results
Twenty-three patients were included in this study. On average, the use of intraoperative CT added 24.4 min in operative time. Five patients (21.7%) required implant adjustment after O-arm spin. Fourteen patients underwent additional post-operative CT. No secondary revision surgeries were attempted after any post-operative CT.
Conclusions
Our study suggests that intra-operative CT scan, compared to post-operative CT scan, can be utilized to prevent take-back surgery for misplaced implants and allow for adjustment in real-time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Allegheny General Hospital, 320 E North Ave, Pittsburgh, PA, 15201, USA.
- Allegheny General Hospital, 320 E North Ave, Pittsburgh, PA, 15201, USA. mattchilton1@gmail.com.
ORCID-Profile: Matthew Chilton
Zitieren
APA
Kevin, M., William, H., Chilton, M., Michael, M., Alice, H., Gregory, A., Daniel, A., & Erik, H. J. (2024). Intraoperative computerised tomography scan for percutaneous fixation of the pelvis: a retrospective case series. International Orthopaedics. https://doi.org/10.1007/s00264-024-06265-7
Vancouver
Kevin M, William H, Chilton M, Michael M, Alice H, Gregory A, et al. Intraoperative computerised tomography scan for percutaneous fixation of the pelvis: a retrospective case series. International Orthopaedics. 2024. doi:10.1007/s00264-024-06265-7
BibTeX
@article{Kevin2024,
author = {Kevin, Monahan and William, Hogan and Chilton, Matthew and Michael, Maher and Alice, Hughes and Gregory, Altman and Daniel, Altman and Erik, Hammarstedt Jon},
title = {Intraoperative computerised tomography scan for percutaneous fixation of the pelvis: a retrospective case series},
journal = {International Orthopaedics},
year = {2024},
doi = {10.1007/s00264-024-06265-7}
}
EUVIMED