EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Collared Cementless Femoral Components Reduce the Revision Rates in Primary Total Hip Arthroplasty Using the Direct Anterior Approach: An Australian Orthopaedic Association National Joint Replacement Registry Study

Siddharth Rele, Edward O'Bryan, Carl Holder, Peter L Lewis, Claudia Di Bella

The Journal of Arthroplasty · 2024-09 · 39 (9) · S340-S346.e2

DOI: 10.1016/j.arth.2024.05.009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2024-09. Verfasst von Siddharth Rele und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, St Vincent's Hospital, University of Melbourne, Fitzroy, Victoria, Australia. Hauptthemen laut MEDLINE: Reoperation, Arthroplasty, Replacement, Hip, Registries, Prosthesis Failure. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: An increased risk of periprosthetic fracture and aseptic loosening is reported when the direct anterior approach (DAA) is used for total hip arthroplasty (THA), especially with cementless implants. We assessed the rate of revision comparing collared and collarless femoral stems when using the DAA for THA. METHODS: We used data from the Australian Orthopaedic Association National Joint Replacement Registry for primary THA for osteoarthritis inserted with the DAA between January 2015 and December 2022. There were 48,567 THAs that used the DAA (26,690 collarless cementless, 10,161 collared cementless, and 11,716 cemented). Cumulative percent revision was calculated for all-cause revision, revision for periprosthetic femoral fractures, and aseptic femoral stem loosening. Cox proportional hazard ratios [HRs] were used to compare the revision of collared and collarless cementless stems. We also compared collared cementless stems and cemented stems. RESULTS: A higher rate of all-cause revision within 3 months of surgery was observed with collarless compared to collared cementless implants (HR: 1.99 [95% confidence interval (CI), 1.56 to 2.54]; P < .001). Similarly, collarless cementless implants were associated with a greater rate of revision for fracture in the first 6 months (HR: 2.90 [95% CI, 1.89 to 4.45]; P < .001) and after 6 months (HR 10.04 [95% CI 1.38 to 73.21]; P = .02), as well as an increased rate of revision for aseptic loosening after 2 years (HR: 5.76 [95% CI, 1.81 to 18.28], P = .003). Collared cementless and cemented stems performed similarly. CONCLUSION: Collared stems were associated with a reduced rate of all-cause revision for cementless THA performed via the DAA. The reduction in risk may be due to protection from periprosthetic femoral fracture and aseptic loosening.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ReoperationArthroplasty, Replacement, HipRegistriesProsthesis FailureHip ProsthesisPeriprosthetic FracturesProsthesis DesignHumansMaleFemaleAgedAustraliaMiddle AgedOsteoarthritis, HipAged, 80 and overBone CementsFemur

Stichwörter der Autor:innen

cementless stemscollared stemsdirect anterior approachrevisiontotal hip arthroplasty

Substanzen

Bone Cements

Autor:innen und Institutionen

  • Department of Surgery, St Vincent's Hospital, University of Melbourne, Fitzroy, Victoria, Australia.
  • Orthopaedic Department, Alfred Health, Melbourne, Victoria, Australia.
  • South Australian Health and Medical Research Institute (SAHMRI), Adelaide, South Australia, Australia.
  • Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), Adelaide, South Australia, Australia; University of Adelaide Medical School, Adelaide, South Australia, Australia.
  • Department of Surgery, The University of Melbourne, Eastern Hill Campus, Fitzroy, Victoria, Australia; Department of Orthopaedics, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia; Victorian Bone and Joint…

Zitieren

APA

Rele, S., O'Bryan, E., Holder, C., Lewis, P. L., & Di Bella, C. (2024). Collared Cementless Femoral Components Reduce the Revision Rates in Primary Total Hip Arthroplasty Using the Direct Anterior Approach: An Australian Orthopaedic Association National Joint Replacement Registry Study. The Journal of Arthroplasty, 39(9), S340-S346.e2. https://doi.org/10.1016/j.arth.2024.05.009

Vancouver

Rele S, O'Bryan E, Holder C, Lewis PL, Di Bella C. Collared Cementless Femoral Components Reduce the Revision Rates in Primary Total Hip Arthroplasty Using the Direct Anterior Approach: An Australian Orthopaedic Association National Joint Replacement Registry Study. The Journal of Arthroplasty. 2024;39(9):S340-S346.e2. doi:10.1016/j.arth.2024.05.009

BibTeX
@article{Rele2024,
  author = {Rele, Siddharth and O'Bryan, Edward and Holder, Carl and Lewis, Peter L and Di Bella, Claudia},
  title = {Collared Cementless Femoral Components Reduce the Revision Rates in Primary Total Hip Arthroplasty Using the Direct Anterior Approach: An Australian Orthopaedic Association National Joint Replacement Registry Study},
  journal = {The Journal of Arthroplasty},
  year = {2024},
  volume = {39},
  number = {9},
  pages = {S340--S346.e2},
  doi = {10.1016/j.arth.2024.05.009}
}
Kostenlos starten →