Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Arthroplasty, 2026. Verfasst von David T Wallace und 4 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedic Research Unit, The Prince Charles Hospital, Chermside, Queensland, Australia; School of Mechanical, Medical and Process Engineering, Facu…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Reoperation, Hip Prosthesis, Prosthesis Design. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Department of Health and Aged Care, Australian Government.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Registry and industry data show increasing utilization of large (36 mm) heads in primary total hip arthroplasty (THA). Recent analysis of the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) has reported reduced dislocation rates with 36 mm heads compared to 32- and 28-mm heads; however, the effect of age, fixation, approach, cup size, and bearing surface upon revision risk and head size has not been examined, with little data on all-cause revision. METHODS: The AOANJRR data were examined for all ceramic and metal head THA with highly crosslinked polyethylene between September 1999 and December 2022. There were 272,258 THAs identified. Cumulative percent revision (CPR) following THA was examined with further subanalysis of age, fixation, approach, cup size, and bearing surface for 32- and 36-mm heads. RESULTS: The CPR was higher for 36 mm heads from 1 month (HR [hazard ratio] 1.14 (1.08 to 1.20), P < 0.001). Subgroup analysis showed these differences varied depending on age, sex, approach, cup size, and bearing surface. There were differences in reasons for revision between head sizes, with significantly more revisions with 36 mm heads for fracture (HR 1.30 (1.18 to 1.42), P < 0.001), particularly for ≥ 65-year-olds, and loosening (HR 1.21 (1.09 to 1.34, P < 0.001), and significantly more revisions for dislocation (to a lesser degree) with 32 mm heads (HR 1.18 (1.07 to 1.30), P < 0.001). CONCLUSIONS: Our study shows an association between larger head size and increased CPR. This difference is most clearly seen in metal-on-highly crosslinked polyethylene articulations, anterior approach, and 54- to 55-mm cup size in men < 65 years, although it still exists to a lesser extent in men ≥ 65 years. For women, the pattern was similar, although not as apparent. Comparing 36- to 32-mm heads, 36 mm showed reduced early dislocation; however, revision for fracture and loosening was increased. With an increasing trend toward larger head sizes both in the AOANJRR and elsewhere, consideration must be given in these particular subgroups as to whether larger head size confers the intended survival advantages.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipReoperationHip ProsthesisProsthesis DesignProsthesis FailureHumansFemaleMaleAgedRegistriesAustraliaMiddle AgedAdultAged, 80 and over

Stichwörter der Autor:innen

CPRdislocationfracturehead sizelooseningsurvival

Autor:innen und Institutionen

  • Orthopaedic Research Unit, The Prince Charles Hospital, Chermside, Queensland, Australia; School of Mechanical, Medical and Process Engineering, Faculty of Engineering, Queensland University of Technology, Queensland, A…
  • South Australian Health and Medical Research Institute (SAHMRI), Adelaide, Australia.
  • Clinical Studies Unit, Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), Adelaide, Australia.

Förderung

  • Department of Health and Aged Care, Australian Government

Zitieren

APA

Wallace, D. T., Whitehouse, S. L., Du, P., Wall, C. J., & Crawford, R. W. (2026). Does a 36-mm Head Increase Cumulative Revision Rate in Total Hip Arthroplasty When Compared to a 32-mm Head? A Study From the Australian Orthopaedic Association National Joint Replacement Registry. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2025.08.014

Vancouver

Wallace DT, Whitehouse SL, Du P, Wall CJ, Crawford RW. Does a 36-mm Head Increase Cumulative Revision Rate in Total Hip Arthroplasty When Compared to a 32-mm Head? A Study From the Australian Orthopaedic Association National Joint Replacement Registry. The Journal of Arthroplasty. 2026. doi:10.1016/j.arth.2025.08.014

BibTeX
@article{Wallace2026,
  author = {Wallace, David T and Whitehouse, Sarah L and Du, Peiyao and Wall, Christopher J and Crawford, Ross W},
  title = {Does a 36-mm Head Increase Cumulative Revision Rate in Total Hip Arthroplasty When Compared to a 32-mm Head? A Study From the Australian Orthopaedic Association National Joint Replacement Registry},
  journal = {The Journal of Arthroplasty},
  year = {2026},
  doi = {10.1016/j.arth.2025.08.014}
}
Kostenlos starten →