Isolated Liner Exchange Versus All-Component Revision for Instability After Total Knee Arthroplasty
The Journal of Arthroplasty · 2024-03 · 39 (3) · 778-781
DOI: 10.1016/j.arth.2023.09.007 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2024-03. Verfasst von Eytan M Debbi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Cedars-Sinai Medical System, Los Angeles, California; Department of Orthopedic Surgery, Adult Reconstruction and Jo…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 12 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Instability is a common cause for revision total knee arthroplasty (TKA). The risks and benefits of polyethylene liner exchange (LE) as compared to full metal component revision continue to be debated. The purpose of this study was to investigate the success rate and complication profiles of revision TKA for instability based on surgical procedure. METHODS: This was a retrospective study of patients undergoing revision TKA for instability from 2015 to 2019. Patients with prior revisions were excluded. 42 patients undergoing isolated polyethylene LE without an increase in constraint were compared with 48 patients undergoing full component revision revision (FCR) of both tibial and femoral components. The primary outcome was differences in rerevision for instability. Noninstability reoperations, 90-day readmissions, and lengths-of-stay were also compared. RESULTS: LEs had a 10.1% higher rerevision for instability rate that approached statistical significance (LE 14.3% versus FCR 4.2%, P = .092). Additionally, FCR had a 4.2% rate of aseptic loosening and a 4.2% rate of periprosthetic-joint-infection, whereas LE had none (P = .181). FCR also had a longer length-of-stay (FCR 3.0 ± 1.3 versus LE: 1.8 ± 0.9 days, P < .001). No differences were found in 90-day readmissions (LE 7.1% versus FCR 4.2%, P = .661). CONCLUSION: All component revision may have a higher success rate than isolated LE in addressing instability but is associated with higher rates of surgical complications. With appropriate patient selection and risk-benefit discussion, isolated LE may be a reasonable surgical option for TKA instability with a lower complication profile and length-of-stay.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Cedars-Sinai Medical System, Los Angeles, California; Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York.
- Department of Orthopedic Surgery, Cedars-Sinai Medical System, Los Angeles, California.
Zitieren
APA
Debbi, E. M., Durst, C. R., Rezzadeh, K. T., Spitzer, A. I., & Rajaee, S. S. (2024). Isolated Liner Exchange Versus All-Component Revision for Instability After Total Knee Arthroplasty. The Journal of Arthroplasty, 39(3), 778-781. https://doi.org/10.1016/j.arth.2023.09.007
Vancouver
Debbi EM, Durst CR, Rezzadeh KT, Spitzer AI, Rajaee SS. Isolated Liner Exchange Versus All-Component Revision for Instability After Total Knee Arthroplasty. The Journal of Arthroplasty. 2024;39(3):778-781. doi:10.1016/j.arth.2023.09.007
BibTeX
@article{Debbi2024,
author = {Debbi, Eytan M and Durst, Caleb R and Rezzadeh, Kevin T and Spitzer, Andrew I and Rajaee, Sean S},
title = {Isolated Liner Exchange Versus All-Component Revision for Instability After Total Knee Arthroplasty},
journal = {The Journal of Arthroplasty},
year = {2024},
volume = {39},
number = {3},
pages = {778--781},
doi = {10.1016/j.arth.2023.09.007}
}