Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2023. Verfasst von Joshua R Labott und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Osteoarthritis, Knee. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 11 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Higher failure rates of unicompartmental knee arthroplasty (UKA) are seen with lower surgical volume. Surgical techniques that introduce less variability improving implant positioning may lead to improved survivorship. A femur-first (FF) technique has been described, but survivorship data compared to traditional tibia-first (TF) technique are under-reported. We report the results of mobile-bearing UKA using the FF technique compared to the TF technique with emphasis on implant position and survivorship. METHODS: A total of 430 UKAs were performed by a single surgeon between 2007 and 2020. After 2012, there were 141 consecutive UKAs performed with the FF technique which were compared with 147 consecutive UKAs prior. Mean follow-up was 6 years (range, 2 to 13 years), average age was 63 years (range, 23 to 92 years), and there were 132 women. Postoperative radiographs were reviewed to determine implant positioning. Survivorship analyses were performed using Kaplan-Meier curves. RESULTS: The FF resulted in significantly thinner polyethylene (3.4 ± 0.7 mm versus 3.7 ± 0.9 mm) (P = .002) and 4 mm or less bearing thickness in 94% of cases. At 5 years, there was an early trend toward improved survivorship free from component revision (98% for the FF group and 94% for the TF [P = .35]). The FF cohort had higher Knee Society Functional scores at final follow-up (P < .001). CONCLUSION: Compared to traditional TF technique, the FF was more bone-preserving and improved radiographic positioning. The FF technique is an alternative method for mobile-bearing UKA and was associated with an improvement in implant survivorship and function.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeHumansFemaleMiddle AgedTreatment OutcomeReoperationProsthesis FailureFemurPolyethyleneKnee JointRetrospective Studies

Stichwörter der Autor:innen

arthroplastymobile bearingsurgical techniquesurvivorshipunicompartmental

Substanzen

Polyethylene

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota; Chang Gung Memorial Hospital, Taoyuan, Taiwan.

Zitieren

APA

Labott, J. R., Carlson, S. W., Lee, S. H., & Sierra, R. J. (2023). Femur-First Technique for Mobile Bearing Unicompartmental Knee Arthroplasty Results in Decreased Implant Variability and Early Improvements in Function and Survivorship. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2023.02.012

Vancouver

Labott JR, Carlson SW, Lee SH, Sierra RJ. Femur-First Technique for Mobile Bearing Unicompartmental Knee Arthroplasty Results in Decreased Implant Variability and Early Improvements in Function and Survivorship. The Journal of Arthroplasty. 2023. doi:10.1016/j.arth.2023.02.012

BibTeX
@article{Labott2023,
  author = {Labott, Joshua R and Carlson, Samuel W and Lee, Sheng-Hsun and Sierra, Rafael J},
  title = {Femur-First Technique for Mobile Bearing Unicompartmental Knee Arthroplasty Results in Decreased Implant Variability and Early Improvements in Function and Survivorship},
  journal = {The Journal of Arthroplasty},
  year = {2023},
  doi = {10.1016/j.arth.2023.02.012}
}
Kostenlos starten →