Patient Preferences for Tracker Pin–Related Incision Configurations in Robotic-Assisted Total Knee Arthroplasty
Arthroplasty Today · 2026-10 · 41 · 102141
DOI: 10.1016/j.artd.2026.102141 ↗Kurz gefasst
Fachartikel in der Zeitschrift Arthroplasty Today, 2026-10. Verfasst von Varah Yuenyongviwat und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, Faculty of Medicine, Prince of Songkla University, Songkhla, Thailand. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Prince of Songkla University Faculty of Medicine.
Abstract (Originalsprache)
Background
Robotic-assisted total knee arthroplasty (TKA) requires tracker pin placement, which may result in different incision configurations. Although clinical outcomes across pin placement strategies appear comparable, patient preferences regarding incision design remain unclear.
Methods
This cross-sectional observational study included 101 patients with knee osteoarthritis who were recruited consecutively at a tertiary university hospital. Three tracker pin-related incision configurations were presented using standardized lower-limb models: (A) all-inside, consisting of the longest single midline incision; (B) femoral pin in-tibial pin out, consisting of a medium-length midline incision plus two tibial stab incisions; and (C) pin outside, consisting of the shortest midline incision plus four stab incisions. Participants rated each design using a 5-point Likert scale and selected a single preferred option. Cosmetic and recovery concerns were assessed using five Likert-scale items.
Results
Postoperative scarring received the highest concern ratings, followed by recovery time, whereas concern about incision length and the number of incisions was lower. Preference scores showed a numerical ranking: all-inside 4.0 [interquartile range (IQR), 3.0-4.0]; femoral pin in-tibial pin out 3.0 [IQR, 2.0-4.0]; and pin outside 3.0 [IQR, 2.0-3.0], without a statistically significant difference (Friedman χ² = 5.52, P = .063). When selecting a single preferred option, 46.5% chose all-inside, 25.7% femoral pin in-tibial pin out, and 27.7% pin outside.
Conclusions
No clear differences in overall preference were observed among the three incision configurations. Preoperative counseling should address expectations regarding scar appearance, wound care, and recovery trajectory rather than emphasizing incision configuration alone in robotic-assisted TKA.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics, Faculty of Medicine, Prince of Songkla University, Songkhla, Thailand.
Förderung
- Prince of Songkla University Faculty of Medicine
Zitieren
APA
Yuenyongviwat, V., Anusitviwat, C., Hongnaparak, T., Tuntarattanapong, P., & Iamthanaporn, K. (2026). Patient Preferences for Tracker Pin–Related Incision Configurations in Robotic-Assisted Total Knee Arthroplasty. Arthroplasty Today, 41, 102141. https://doi.org/10.1016/j.artd.2026.102141
Vancouver
Yuenyongviwat V, Anusitviwat C, Hongnaparak T, Tuntarattanapong P, Iamthanaporn K. Patient Preferences for Tracker Pin–Related Incision Configurations in Robotic-Assisted Total Knee Arthroplasty. Arthroplasty Today. 2026;41:102141. doi:10.1016/j.artd.2026.102141
BibTeX
@article{Yuenyongviwat2026,
author = {Yuenyongviwat, Varah and Anusitviwat, Chirathit and Hongnaparak, Theerawit and Tuntarattanapong, Pakjai and Iamthanaporn, Khanin},
title = {Patient Preferences for Tracker Pin–Related Incision Configurations in Robotic-Assisted Total Knee Arthroplasty},
journal = {Arthroplasty Today},
year = {2026},
volume = {41},
pages = {102141},
doi = {10.1016/j.artd.2026.102141}
}
EUVIMED