Effectiveness of Periarticular Pin Tracker Placement Through a Single Main Incision in Robotic-Assisted Total Knee Arthroplasty: Technical Note and Short-Term Results
Medicina · 20.10.2024 · 60 (10) · 1720
DOI: 10.3390/medicina60101720 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medicina, online erschienen am 20.10.2024. Verfasst von Ji-Hoon Baek und 6 weiteren Autor:innen. Beteiligte Einrichtung: Joint & Arthritis Research, Department of Orthopaedic Surgery, Himchan Hospital, Seoul 07999, Republic of Korea. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background and Objectives: Robotic-assisted total knee arthroplasty (TKA) is gaining popularity worldwide, leading to a potential increase in the number of pin tracker–related complications. This study determined the effectiveness of periarticular pin tracker placement in the distal femur and proximal tibia through a single main incision during robotic-assisted TKA over a minimum follow-up period of 6 months. Materials and Methods: A consecutive series of 149 TKAs was performed in 108 patients using the triathlon posterior-stabilized total knee prosthesis with a robotic-assisted system at our hospital from December 2023 to February 2024. Clinical outcomes and complications associated with pin tracker sites, including pin-site infection, neurovascular injury, hematoma, soft-tissue morbidity, and pin-site fracture, were assessed.
Results
The mean Knee Society knee score improved from 42.5 preoperatively to 76.3 points at the final follow-up, whereas the mean Knee Society function score improved from 43.1 preoperatively to 78.1 points at the final follow-up (both p < 0.05). No patient experienced any minor or major complications related to the use of pin trackers in the distal femur and proximal tibia.
Conclusions
This periarticular technique that uses pin trackers in the distal femur and proximal tibia through a single main incision could be a useful option for orthopedic surgeons while performing robotic-assisted TKA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Joint & Arthritis Research, Department of Orthopaedic Surgery, Himchan Hospital, Seoul 07999, Republic of Korea.
- Joint & Arthritis Research, Department of Neurosurgery, Himchan Hospital, Seoul 07999, Republic of Korea.
Zitieren
APA
Baek, J. H., Lee, S. C., Kim, T., Heo, J., Lee, D. N., Ahn, H. S., & Nam, C. H. (2024). Effectiveness of Periarticular Pin Tracker Placement Through a Single Main Incision in Robotic-Assisted Total Knee Arthroplasty: Technical Note and Short-Term Results. Medicina, 60(10), 1720. https://doi.org/10.3390/medicina60101720
Vancouver
Baek JH, Lee SC, Kim T, Heo J, Lee DN, Ahn HS, et al. Effectiveness of Periarticular Pin Tracker Placement Through a Single Main Incision in Robotic-Assisted Total Knee Arthroplasty: Technical Note and Short-Term Results. Medicina. 2024;60(10):1720. doi:10.3390/medicina60101720
BibTeX
@article{Baek2024,
author = {Baek, Ji-Hoon and Lee, Su Chan and Kim, Taehyeon and Heo, Juneyoung and Lee, Dong Nyoung and Ahn, Hye Sun and Nam, Chang Hyun},
title = {Effectiveness of Periarticular Pin Tracker Placement Through a Single Main Incision in Robotic-Assisted Total Knee Arthroplasty: Technical Note and Short-Term Results},
journal = {Medicina},
year = {2024},
volume = {60},
number = {10},
pages = {1720},
doi = {10.3390/medicina60101720}
}