Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2024-04. Verfasst von Michael Stetzer und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Periprosthetic Fractures, Robotic Surgical Procedures. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: While robotic-arm assisted total knee arthroplasty (RA-TKA) has seen a major increase in its utilization, it requires bone array pins to be fixed into the femur and tibia, which intrinsically carries a risk. As it is currently off-label with some robotic platforms to place pins intraincisional, we aimed to evaluate the safety of intraincisional pin placement during RA-TKAs. METHODS: A prospective cohort of 2,343 patients who underwent RA-TKA at a North American Healthcare System between January 2018 and March 2022 was included. Primary outcomes included periprosthetic fracture or infection (eg, superficial or deep). Secondary outcomes included 1-year reoperation rate due to any cause. Cases were retrospectively reviewed to determine whether complications could be attributed to metaphyseal intraincisional pin placement (4.0 mm pins; two tibial and two femoral). The 90-day follow-up was 100% and the 1-year follow-up rate was 70.6% (n = 1,655). RESULTS: The pin-site related periprosthetic fracture incidence at 90 days was 0.09% (2 out of 2,343). The 90-day infection incidence was 1.4% (superficial: 22; deep: 13). The 1-year reoperation rate was 1.8% (29 out of 1,655). The most common causes of reoperation at 1-year were deep infection (n = 14; 0.83%), superficial infection (n = 3; 0.18%), periprosthetic fracture, mechanical symptoms, instability, and hematoma (n = 2; 0.12% for each). CONCLUSIONS: One in 1,172 patients may experience a pin-related periprosthetic fracture after RA-TKA with intraincisional bone array pin placement. There was a low 90-day infection incidence and reoperations within 1-year after RA-TKA were rare.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio.
Zitieren
APA
Stetzer, M., Bircher, J., Klika, A. K., Rullán, P. J., Bloomfield, M. M., Krebs, V. E., Molloy, R. M., & Piuzzi, N. S. (2024). Intraincisional Pin Placement is Safe for Robotic-Assisted Total Knee Arthroplasty. The Journal of Arthroplasty, 39(4), 910-915.e1. https://doi.org/10.1016/j.arth.2023.10.050
Vancouver
Stetzer M, Bircher J, Klika AK, Rullán PJ, Bloomfield MM, Krebs VE, et al. Intraincisional Pin Placement is Safe for Robotic-Assisted Total Knee Arthroplasty. The Journal of Arthroplasty. 2024;39(4):910-915.e1. doi:10.1016/j.arth.2023.10.050
BibTeX
@article{Stetzer2024,
author = {Stetzer, Michael and Bircher, James and Klika, Alison K and Rullán, Pedro J and Bloomfield, Michael M and Krebs, Viktor E and Molloy, Robert M and Piuzzi, Nicolas S},
title = {Intraincisional Pin Placement is Safe for Robotic-Assisted Total Knee Arthroplasty},
journal = {The Journal of Arthroplasty},
year = {2024},
volume = {39},
number = {4},
pages = {910--915.e1},
doi = {10.1016/j.arth.2023.10.050}
}
EUVIMED