A randomised trial to compare Truview PCD ® , C-MAC ® and Macintosh laryngoscopes in paediatric airway management
Asian Journal of Anesthesiology · 2017
DOI: 10.1016/j.aja.2017.06.001 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Asian Journal of Anesthesiology, 2017. Verfasst von Ranju Singh und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesiology & Critical Care, Lady Hardinge Medical College & Associated Shrimati Sucheta Kriplani Hospital, New Delhi, India. Elect…. Hauptthemen laut MEDLINE: Laryngoscopes. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
AIM: To evaluate and compare the Truview PCD and C-MAC laryngoscopes to the standard Macintosh laryngoscope in paediatric patients. METHODS: One hundred and fifty ASA I-II patients in the age group of 1-6 years (10-20 kg) scheduled for elective surgery were randomised into three equal groups for laryngoscopy and intubation with either Truview PCD (Group T), C-MAC (Group C) or Macintosh (Group M) laryngoscopes under general anaesthesia. Percentage of glottic opening (POGO) score, application of external laryngeal manoeuvre, time to intubation, number of attempts at intubation, failed intubations, episodes of desaturation and trauma caused were recorded and statistically analysed. A p value of
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anaesthesiology & Critical Care, Lady Hardinge Medical College & Associated Shrimati Sucheta Kriplani Hospital, New Delhi, India. Electronic address: ranjusingh1503@yahoo.com.
- Department of Anaesthesiology & Critical Care, Lady Hardinge Medical College & Associated Shrimati Sucheta Kriplani Hospital, New Delhi, India. Electronic address: kumarnishant@yahoo.co.uk.
- Department of Anaesthesiology & Critical Care, Lady Hardinge Medical College & Associated Shrimati Sucheta Kriplani Hospital, New Delhi, India. Electronic address: ajayaruna112@rediffmail.com.
Zitieren
APA
Singh, R., Kumar, N., & Jain, A. (2017). A randomised trial to compare Truview PCD ® , C-MAC ® and Macintosh laryngoscopes in paediatric airway management. Asian Journal of Anesthesiology. https://doi.org/10.1016/j.aja.2017.06.001
Vancouver
Singh R, Kumar N, Jain A. A randomised trial to compare Truview PCD ® , C-MAC ® and Macintosh laryngoscopes in paediatric airway management. Asian Journal of Anesthesiology. 2017. doi:10.1016/j.aja.2017.06.001
BibTeX
@article{Singh2017,
author = {Singh, Ranju and Kumar, Nishant and Jain, Aruna},
title = {A randomised trial to compare Truview PCD ® , C-MAC ® and Macintosh laryngoscopes in paediatric airway management},
journal = {Asian Journal of Anesthesiology},
year = {2017},
doi = {10.1016/j.aja.2017.06.001}
}