Use of Video Laryngoscope to Reduce Complications of Transesophageal Echocardiography Probe Insertion in Children
Journal of Cardiothoracic and Vascular Anesthesia · 2026
DOI: 10.1053/j.jvca.2025.11.033 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2026. Verfasst von G Gayathri und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiothoracic and Vascular Anaesthesia, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, India. Hauptthemen laut MEDLINE: Echocardiography, Transesophageal, Laryngoscopes, Laryngoscopy, Intraoperative Complications. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
OBJECTIVES: To test the hypothesis of whether using a video laryngoscope reduces complications related to transesophageal echocardiography (TEE) probe insertion in children. DESIGN: Randomized controlled study. SETTING: Pediatric cardiac surgical operating rooms in a tertiary care level hospital. PARTICIPANTS: One hundred thirty children aged 0 to 18 years undergoing elective cardiac surgery. INTERVENTIONS: TEE probe insertion. MEASUREMENTS AND MAIN RESULTS: The patients were randomized into 2 groups: conventional (C) group (n = 64) and video laryngoscopy (VL) group (n = 66). The primary endpoint of the study was the incidence of oropharyngeal injury. The secondary endpoints were the number of attempts required for successful TEE probe insertion and the relation between the esophageal inlet and the larynx. The overall incidence of oropharyngeal injuries was 7.7%, with 4 injuries (6.3%) occurring in the C group and 6 injuries (9.1%) occurring in the VL group (p = 0.543). Most children (90.8%) required only 1 attempt to insert the TEE probe, with no significant difference between groups (p = 0.579). A higher percentage increase in mean blood pressure during probe insertion and a higher heart rate increase after probe insertion were observed in the VL group (p < 0.05). The most common relationship with the larynx was posterior (62%), followed by left posterolateral (20.9%) and right posterolateral (17.1%). CONCLUSIONS: VL does not demonstrate superiority over conventional methods of TEE probe insertion in children regarding injury incidence or first-attempt success rate.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiothoracic and Vascular Anaesthesia, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, India.
- Division of Cardiothoracic and Vascular Anaesthesia, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, India. Electronic address: koshy61@gmail.com.
Zitieren
APA
Gayathri, G., Divya Jacob, P., Nayanar, V. K. N., Vipin Raj, V., Babu, S., Unnikrishnan, K. P., & Koshy, T. (2026). Use of Video Laryngoscope to Reduce Complications of Transesophageal Echocardiography Probe Insertion in Children. Journal of Cardiothoracic and Vascular Anesthesia. https://doi.org/10.1053/j.jvca.2025.11.033
Vancouver
Gayathri G, Divya Jacob P, Nayanar VKN, Vipin Raj V, Babu S, Unnikrishnan KP, et al. Use of Video Laryngoscope to Reduce Complications of Transesophageal Echocardiography Probe Insertion in Children. Journal of Cardiothoracic and Vascular Anesthesia. 2026. doi:10.1053/j.jvca.2025.11.033
BibTeX
@article{Gayathri2026,
author = {Gayathri, G and Divya Jacob, P and Nayanar, V Krishna Narayanan and Vipin Raj, V and Babu, Saravana and Unnikrishnan, K P and Koshy, Thomas},
title = {Use of Video Laryngoscope to Reduce Complications of Transesophageal Echocardiography Probe Insertion in Children},
journal = {Journal of Cardiothoracic and Vascular Anesthesia},
year = {2026},
doi = {10.1053/j.jvca.2025.11.033}
}
EUVIMED