EUVIMEDEUVIMED entdecken
EvaluationsstudieVergleichsstudie

Evaluation of cutting efficiency, surface roughness, and diameter of diamond rotary instruments on laboratory and computer-aided designed and computer-aided manufactured resin composite materials

Selva Malar Munusamy, Yee Shien Chung, Mohideen Salihu Farook, Siti Fauzza Ahmad, Zubaidah Zanul Abidin

The Journal of the American Dental Association · 2026-06 · 157 (6) · 629-638

DOI: 10.1016/j.adaj.2025.11.007 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift The Journal of the American Dental Association, 2026-06. Verfasst von Selva Malar Munusamy und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia. Electronic address: selvamalar@um.edu.my. Hauptthemen laut MEDLINE: Computer-Aided Design, Diamond, Dental Instruments, Dental Materials. Die Arbeit nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Replacement of diamond rotary instruments is critical for optimizing cutting efficiency. The authors aimed to assess and compare the cutting efficiency, surface roughness, and diameter of coarse-grit and medium-grit diamond rotary instruments after repeated cuts on indirect composite materials. METHODS: Medium-grit (115 μm) and coarse-grit (150 μm) diamond rotary instruments (NTI; Kahla GmbH) were tested on 2-mm-thick Ceramage (Shofu) (CM) and Lava Ultimate (3M ESPE) (LU) specimens and divided into 4 groups of 8 samples per group: LU-coarse, LU-medium, CM-coarse, and CM-medium. A high-speed handpiece with a cutting load of 0.9 N, speed of 400,000 rpm, and water flow rate of 25 mL/min was used. Cutting efficiency was assessed by measuring cutting time and surface roughness (roughness average) was measured using a surface analyzer and diameter was measured using calipers. Data were analyzed statistically using 2-way analysis of variance (ANOVA), followed by 1-way ANOVA with Tukey honestly significant difference post hoc test (P < .05). For comparison between cuts, 1-way repeated measures ANOVA was used for cutting time and surface roughness and paired samples t test was used for diameter (P < .05). RESULTS: Coarse-grit diamond rotary instruments had significantly higher (P < .05) cutting efficiency than medium-grit diamond rotary instruments at cut 1. At cut 10, significant differences (P < .05) in mean cutting time, surface roughness, and diameter were observed, with coarse-grit diamond rotary instruments having pronounced wear patterns compared with medium-grit diamond rotary instruments. CONCLUSIONS: Differences in cutting time, surface roughness, and diameter after repeated cuts on indirect composite materials was instrument dependent. Coarse-grit rotary instruments had greater deterioration and wear than medium-grit rotary instruments. PRACTICAL IMPLICATIONS: Medium-grit diamond rotary instruments can be suggested for prolonged use (cut 10) on computer-aided designed and computer-aided manufactured composites. Diamond rotary instruments are recommended for replacement after cut 10 or 5 minutes of use on indirect composite materials.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computer-Aided DesignDiamondDental InstrumentsDental MaterialsEquipment DesignDental High-Speed EquipmentSurface PropertiesMaterials TestingMicroscopy, Electron, Scanning

Stichwörter der Autor:innen

CAD-CAM compositeDiamond rotary instrumentscutting efficiencylaboratory resin compositesurface roughnesswear

Substanzen

DiamondDental Materials

Autor:innen und Institutionen

  • Department of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia. Electronic address: selvamalar@um.edu.my.
  • Department of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia.

Zitieren

APA

Munusamy, S. M., Chung, Y. S., Farook, M. S., Ahmad, S. F., & Zanul Abidin, Z. (2026). Evaluation of cutting efficiency, surface roughness, and diameter of diamond rotary instruments on laboratory and computer-aided designed and computer-aided manufactured resin composite materials. The Journal of the American Dental Association, 157(6), 629-638. https://doi.org/10.1016/j.adaj.2025.11.007

Vancouver

Munusamy SM, Chung YS, Farook MS, Ahmad SF, Zanul Abidin Z. Evaluation of cutting efficiency, surface roughness, and diameter of diamond rotary instruments on laboratory and computer-aided designed and computer-aided manufactured resin composite materials. The Journal of the American Dental Association. 2026;157(6):629-638. doi:10.1016/j.adaj.2025.11.007

BibTeX
@article{Munusamy2026,
  author = {Munusamy, Selva Malar and Chung, Yee Shien and Farook, Mohideen Salihu and Ahmad, Siti Fauzza and Zanul Abidin, Zubaidah},
  title = {Evaluation of cutting efficiency, surface roughness, and diameter of diamond rotary instruments on laboratory and computer-aided designed and computer-aided manufactured resin composite materials},
  journal = {The Journal of the American Dental Association},
  year = {2026},
  volume = {157},
  number = {6},
  pages = {629--638},
  doi = {10.1016/j.adaj.2025.11.007}
}
Kostenlos starten →