EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Dual Heat Treatment on the Metallurgy and Mechanical Behaviour of Diamond‐Like Carbon–Coated NiTi Rotary Systems: A Multimethod Investigation

Emmanuel João Nogueira Leal Silva iD, Thyago Oliveira Cardoso, Jorge N R Martins iD, Francisco Manuel Braz Fernandes, Victor Talarico Leal Vieira, Marco A Versiani

International Endodontic Journal · 2026-04 · 59 (4) · 708-717

DOI: 10.1111/iej.70089 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Endodontic Journal, online erschienen am 30.12.2025. Verfasst von Emmanuel João Nogueira Leal Silva und 5 weiteren Autor:innen. Beteiligte Einrichtung: Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil. Hauptthemen laut MEDLINE: Titanium, Nickel, Hot Temperature, Metallurgy. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação para a Ciência e a Tecnologia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To investigate how the application of dual heat treatment during the manufacturing process influences the mechanical performance (flexibility, cyclic fatigue resistance, torsional strength, bending, buckling and cutting efficiency) of rotary nickel‐titanium endodontic instruments. Methodology Rainbow One ( n = 58) and Rainbow Ultra ( n = 58) instruments (size 25/0.06, 25 mm length) were evaluated. Geometric analysis was performed using optical 3D scanning and SEM to assess cutting edges, tip design and surface features. Metallurgical characterisation included EDS for elemental composition and DSC for phase transformation temperatures, with segments obtained from the tip, middle and coronal blade regions. Mechanical testing comprised cyclic fatigue, torsional strength (torque to failure, maximum angle of rotation), bending resistance, buckling strength and cutting efficiency. Standardised testing protocols were applied, including ASTM and ISO guidelines for mechanical assessments. Statistical analyses were conducted using Shapiro–Wilk and Levene tests to assess assumptions, followed by independent Student's t ‐tests, with significance set at 5%.

Results

Both instruments shared equivalent geometries, with deviations below 100 μm, and similar tip designs and surface characteristics. EDS confirmed near‐equiatomic NiTi composition for both systems. DSC revealed R‐phase crystallographic structure at room temperature for both instruments; however, Rainbow Ultra exhibited higher phase transformation temperatures (Rs 35°C vs. 25°C; Rf 45°C vs. 31°C; As 30°C vs. 24°C; Af 50°C vs. 38°C) and a double austenitic transformation peak, compared with a single peak for Rainbow One. Mechanically, Rainbow Ultra demonstrated greater cyclic fatigue resistance (95.5° ± 7 vs. 79.1 ± 6 s), higher maximum rotation angle (485° ± 49° vs. 402° ± 50°), and improved cutting efficiency ( p < 0.05). Rainbow One exhibited higher torque to failure (1.8° ± 0.2 vs. 1.4° ± 0.1 N·cm), greater bending load (369 ± 34 vs. 336 ± 14 gf), and higher buckling resistance (339 ± 32 vs. 273 ± 24 gf), indicating stiffer behaviour.

Conclusions

The application of dual heat treatment during manufacturing significantly influenced the mechanical performance of the tested rotary NiTi instruments. Rainbow Ultra, subjected to sequential heat treatments, exhibited higher flexibility, cyclic fatigue resistance and cutting efficiency, whereas Rainbow One demonstrated greater torsional strength and buckling resistance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumNickelHot TemperatureMetallurgyRoot Canal PreparationDental InstrumentsDiamondDental AlloysMaterials TestingSurface PropertiesEquipment DesignCarbonMicroscopy, Electron, ScanningHumans

Stichwörter der Autor:innen

endodonticsheat treatmentmechanical propertiesmetallurgical propertiesnickel–titanium instruments

Substanzen

TitaniumNickeltitanium nickelideCarbonDiamondDental Alloys

Autor:innen und Institutionen

  • Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil.
  • Rio de Janeiro State University (UERJ), Rio de Janeiro, Brazil.
  • Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal.
  • Grupo de Investigação Em Bioquimica e Biologia Oral, Unidade de Investigação Em Ciências Orais e Biomédicas (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal.
  • Centro de Estudo de Medicina Dentária Baseada Na Evidência (CEMDBE) - Cochrane Portugal, Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal.
  • LIBPhys-FCT UID/FIS/04559/2013, Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal.

ORCID-Profile: Emmanuel João Nogueira Leal Silva, Jorge N R Martins

Förderung

  • Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico
  • Fundação para a Ciência e a Tecnologia

Zitieren

APA

Silva, E. J. N. L., Cardoso, T. O., Martins, J. N. R., Fernandes, F. M. B., Vieira, V. T. L., & Versiani, M. A. (2026). Influence of Dual Heat Treatment on the Metallurgy and Mechanical Behaviour of Diamond‐Like Carbon–Coated NiTi Rotary Systems: A Multimethod Investigation. International Endodontic Journal, 59(4), 708-717. https://doi.org/10.1111/iej.70089

Vancouver

Silva EJNL, Cardoso TO, Martins JNR, Fernandes FMB, Vieira VTL, Versiani MA. Influence of Dual Heat Treatment on the Metallurgy and Mechanical Behaviour of Diamond‐Like Carbon–Coated NiTi Rotary Systems: A Multimethod Investigation. International Endodontic Journal. 2026;59(4):708-717. doi:10.1111/iej.70089

BibTeX
@article{Silva2026,
  author = {Silva, Emmanuel João Nogueira Leal and Cardoso, Thyago Oliveira and Martins, Jorge N R and Fernandes, Francisco Manuel Braz and Vieira, Victor Talarico Leal and Versiani, Marco A},
  title = {Influence of Dual Heat Treatment on the Metallurgy and Mechanical Behaviour of Diamond‐Like Carbon–Coated NiTi Rotary Systems: A Multimethod Investigation},
  journal = {International Endodontic Journal},
  year = {2026},
  volume = {59},
  number = {4},
  pages = {708--717},
  doi = {10.1111/iej.70089}
}
Kostenlos starten →