EUVIMEDEUVIMED entdecken
Crossref

Robust Liver Steatosis Quantification Using Photon-Counting CT in Comparison to PDFF: Validation across Protocols and Cohorts

Xinxin Xu, Jie Yuan, Xinxin Cai, Rong Deng, Jingzhe Li, Xinyu Wu, Huanhuan Chong, Haihong Ma, Yuchen Yang, Yongjun Chen, Zhihan Xu, Bernhard Schmidt und 7 weitere

Academic Radiology · 2026-09

DOI: 10.1016/j.acra.2026.08.094 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Academic Radiology, 2026-09. Verfasst von Xinxin Xu und 18 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China (X.X., J.Y., X.C., R.D., J.L., X.W…. Die Arbeit nennt 32 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: To evaluate the robustness and grading performance of Photon-counting CT (PCCT)-derived fat fraction (CTFF) in liver fat quantification across different protocols and cohorts with varying liver conditions, using proton density fat fraction (PDFF) as the reference. MATERIALS AND METHODS: The prospective study enrolled 297 participants in the Volunteer cohort. Participants were randomly assigned to 120-kVp or 140-kVp groups and subdivided into high- and low-dose subgroups for technical validation. Clinical validation was performed in two cohorts: participants with metabolic dysfunction-associated steatotic liver disease (MASLD, n = 86) and heterogeneous liver diseases (HLD, n = 61). PCCT and PDFF (reference standard for grading) were performed within 1 month. Statistical analyses included intraclass correlation coefficients, Bland-Altman analysis, Mann-Whitney U and Kruskal-Wallis tests, and areas under the receiver operating characteristic (AUC-ROC) and precision-recall curves (AUC-PR). RESULTS: Overall, 444 participants were included (age 44.9 ± 14.3 years; 264 men). In the Volunteer cohort, CTFF showed excellent agreement with PDFF (all ICCs = 0.98; R2 ≥0.96) with a maximum bias of 0.80% (95% CI: 0.70-0.89%), across the whole-cohort and subgroups. No significant differences in the absolute error between PDFF and CTFF were observed across all subgroups (all p > 0.05). CTFF achieved high diagnostic accuracy for both the detection and grading of steatosis with all AUC-ROC and AUC-PR exceeding 0.99. The diagnostic accuracy of CTFF was verified in the MASLD and HLD cohorts. CONCLUSION: CTFF demonstrated excellent agreement with PDFF and consistent diagnostic performance across diverse scan settings and liver conditions.

Schlagwörter

Stichwörter der Autor:innen

CT-derived fat fractionMetabolic dysfunction-associated steatotic liver diseasePhoton-counting CTProton density fat fraction

Autor:innen und Institutionen

  • Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China (X.X., J.Y., X.C., R.D., J.L., X.W., H.C., H.D., R.C., W.L., R.L., F.Y., H.L.); Faculty of Medical Imagi…
  • Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China (X.X., J.Y., X.C., R.D., J.L., X.W., H.C., H.D., R.C., W.L., R.L., F.Y., H.L.); Department of Radiology,…
  • Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China (X.X., J.Y., X.C., R.D., J.L., X.W., H.C., H.D., R.C., W.L., R.L., F.Y., H.L.).
  • Kashi Prefecture Second People's Hospital, Xinjiang, China (H.M.).
  • Department of General Surgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China (Y.Y., Y.C.).
  • CT Collaboration, Siemens Healthineers, Shanghai, China (Z.X.).

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Xu, X., Yuan, J., Cai, X., Deng, R., Li, J., Wu, X., Chong, H., Ma, H., Yang, Y., Chen, Y., Xu, Z., Schmidt, B., Juergens, M., Dong, H., Chang, R., Li, W., Li, R., Yan, F., & Lin, H. (2026). Robust Liver Steatosis Quantification Using Photon-Counting CT in Comparison to PDFF: Validation across Protocols and Cohorts. Academic Radiology. https://doi.org/10.1016/j.acra.2026.08.094

Vancouver

Xu X, Yuan J, Cai X, Deng R, Li J, Wu X, et al. Robust Liver Steatosis Quantification Using Photon-Counting CT in Comparison to PDFF: Validation across Protocols and Cohorts. Academic Radiology. 2026. doi:10.1016/j.acra.2026.08.094

BibTeX
@article{Xu2026,
  author = {Xu, Xinxin and Yuan, Jie and Cai, Xinxin and Deng, Rong and Li, Jingzhe and Wu, Xinyu and Chong, Huanhuan and Ma, Haihong and Yang, Yuchen and Chen, Yongjun and Xu, Zhihan and Schmidt, Bernhard and Juergens, Markus and Dong, Haipeng and Chang, Rui and Li, Weixia and Li, Ruokun and Yan, Fuhua and Lin, Huimin},
  title = {Robust Liver Steatosis Quantification Using Photon-Counting CT in Comparison to PDFF: Validation across Protocols and Cohorts},
  journal = {Academic Radiology},
  year = {2026},
  doi = {10.1016/j.acra.2026.08.094}
}
Kostenlos starten →