EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Reproducibility of lung density quantification across photon-counting and conventional energy-integrating CT: a comparative study

Saman Sotoudeh-Paima iD, Ehsan Samei iD, Ehsan Abadi iD

British Journal of Radiology · 01.11.2025 · 98 (1175) · 1890-1898

DOI: 10.1093/bjr/tqaf103 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift British Journal of Radiology, online erschienen am 10.05.2025. Verfasst von Saman Sotoudeh-Paima und 2 weiteren Autor:innen. Beteiligte Einrichtung: Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University School of Medicine, Durham, …. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Lung. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate how photon-counting CT (PCCT) reproducibly quantifies lung density compared to conventional CT (energy-integrating CT or EICT) and assess the relevance of image quality.

Methods

In this retrospective analysis of a prospective study, subjects underwent acquisitions using EICT and PCCT systems (August-December 2021) on the same day. PCCT projections were reconstructed with 4 kernels and 2 voxel sizes using 2024 reconstruction software (ReconCT, Siemens). PCCT and EICT data were compared using lung density measurements: percentage of low-attenuation areas <−950 Hounsfield unit (HU) (LAA-950), 15th percentile of lung density histogram (Perc15), and mean lung density (MLD). Measurement reproducibility and its relation to image quality parameters (modulation transfer function and noise) were analyzed.

Results

Fifty-four subjects (mean age, 67.4 years ± 9.6, 30 female) were studied. PCCT images had the closest agreement to EICT under identical voxel size and similar kernels, yielding lower LAA-950 (−0.9% ± 2.7, P < 0.05), higher Perc15 (1.4 HU ± 7.9, P > 0.05), and higher MLD (2.4 HU ± 10.8, P > 0.05). At higher PCCT resolution (1024 × 1024 matrix, 0.2 mm slice thickness), the smoother quantitative kernel (Qr36) improved agreement, with differences of −0.5% ± 3.0, −0.1 HU ± 9.8, and 2.8 HU ± 11.1, for LAA-950, Perc15, and MLD (P > 0.05). Image quality parameters strongly correlated with density measurements (RPerc152=85.3%).

Conclusions

PCCT yields reproducible lung density measurements comparable to EICT, with optimal reproducibility dependent on optimized reconstruction parameters and explainable by image quality parameters. Advances in knowledge Lung density reproducibility is critical for integrating PCCT into EICT-based workflows. In our study, PCCT aligned more closely with EICT using similar kernels at identical voxel sizes, or smoother kernels at smaller voxel sizes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedLungHumansFemaleReproducibility of ResultsAgedRetrospective StudiesMalePhotonsMiddle AgedProspective StudiesRadiographic Image Interpretation, Computer-Assisted

Stichwörter der Autor:innen

chest CTenergy-integrating CTlung densityphoton-counting CTreproducibility

Autor:innen und Institutionen

  • Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University School of Medicine, Durham, NC 27705, United States.
  • Department of Electrical & Computer Engineering, Duke University, Durham, NC 27708, United States.
  • Medical Physics Graduate Program, Duke University, Durham, NC 27705, United States.
  • Department of Biomedical Engineering, Duke University, Durham, NC 27708, United States.
  • Department of Physics, Duke University, Durham, NC 27708, United States.

ORCID-Profile: Saman Sotoudeh-Paima, Ehsan Samei, Ehsan Abadi

Förderung

  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Sotoudeh-Paima, S., Samei, E., & Abadi, E. (2025). Reproducibility of lung density quantification across photon-counting and conventional energy-integrating CT: a comparative study. British Journal of Radiology, 98(1175), 1890-1898. https://doi.org/10.1093/bjr/tqaf103

Vancouver

Sotoudeh-Paima S, Samei E, Abadi E. Reproducibility of lung density quantification across photon-counting and conventional energy-integrating CT: a comparative study. British Journal of Radiology. 2025;98(1175):1890-1898. doi:10.1093/bjr/tqaf103

BibTeX
@article{SotoudehPaima2025,
  author = {Sotoudeh-Paima, Saman and Samei, Ehsan and Abadi, Ehsan},
  title = {Reproducibility of lung density quantification across photon-counting and conventional energy-integrating CT: a comparative study},
  journal = {British Journal of Radiology},
  year = {2025},
  volume = {98},
  number = {1175},
  pages = {1890--1898},
  doi = {10.1093/bjr/tqaf103}
}
Kostenlos starten →