EUVIMEDEUVIMED entdecken
Crossref

Using Dual-source Photon-counting Detector CT to Simultaneously Quantify Fat and Iron Content: A Phantom Study

Wanting Hao, Zhihan Xu, Huimin Lin, Fuhua Yan

Academic Radiology · 2024

DOI: 10.1016/j.acra.2024.04.044 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Academic Radiology, 2024. Verfasst von Wanting Hao und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No. 197 Ruijin Er Road, Shanghai 200025, China. Electroni…. Hauptthemen laut MEDLINE: Phantoms, Imaging, Iron, Tomography, X-Ray Computed, Photons. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 50 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: To evaluate the feasibility of using photon-counting detector computed tomography (PCD CT) to simultaneously quantify fat and iron content MATERIALS AND METHODS: Phantoms with pure fat, pure iron and fat-iron deposition were scanned by two tube voltages (120 and 140 kV) and two image quality (IQ) settings (80 and 145). Using an iron-specific three-material decomposition algorithm, virtual noniron (VNI) and virtual iron content (VIC) images were generated at quantum iterative reconstruction (QIR) strength levels 1-4. RESULTS: Significant linear correlations were observed between known fat content (FC) and VNI for pure fat phantoms (r = 0.981-0.999, p 0.05). No significant difference in VNI and VIC at QIR 1-4. CONCLUSION: PCD CT can accurately and simultaneously quantify fat and iron, including scan parameters with lower radiation dose.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingIronTomography, X-Ray ComputedPhotonsAdipose TissueAlgorithmsFeasibility StudiesHumans

Stichwörter der Autor:innen

Computed tomographyFat contentIron contentPhoton-counting detector

Substanzen

Iron

Autor:innen und Institutionen

  • Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No. 197 Ruijin Er Road, Shanghai 200025, China. Electronic address: hwtsjtu08@sjtu.edu.cn.
  • CT Collaboration, Siemens Healthcare Ltd., No. 278 Zhouzhu Road, Shanghai 200025, China. Electronic address: zhihan.xu@siemens-healthineers.com.
  • Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No. 197 Ruijin Er Road, Shanghai 200025, China. Electronic address: lhm12362@rjh.com.cn.
  • Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No. 197 Ruijin Er Road, Shanghai 200025, China; Faculty of Medical Imaging Technology, College of Health Science and Technology…

Zitieren

APA

Hao, W., Xu, Z., Lin, H., & Yan, F. (2024). Using Dual-source Photon-counting Detector CT to Simultaneously Quantify Fat and Iron Content: A Phantom Study. Academic Radiology. https://doi.org/10.1016/j.acra.2024.04.044

Vancouver

Hao W, Xu Z, Lin H, Yan F. Using Dual-source Photon-counting Detector CT to Simultaneously Quantify Fat and Iron Content: A Phantom Study. Academic Radiology. 2024. doi:10.1016/j.acra.2024.04.044

BibTeX
@article{Hao2024,
  author = {Hao, Wanting and Xu, Zhihan and Lin, Huimin and Yan, Fuhua},
  title = {Using Dual-source Photon-counting Detector CT to Simultaneously Quantify Fat and Iron Content: A Phantom Study},
  journal = {Academic Radiology},
  year = {2024},
  doi = {10.1016/j.acra.2024.04.044}
}
Kostenlos starten →