EUVIMEDEUVIMED entdecken
Crossref

A KIT-6 mesoporous silica nanoparticle-based chemiluminescent aptasensor for sensitive detection of 8-Oxo-dG

Maryam Imani, Zahra Vaezi, Hossein Naderi-Manesh

Analytica Chimica Acta · 2026

DOI: 10.1016/j.aca.2026.346279 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Maryam Imani und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biophysics, Faculty of Biological Science, Tarbiat Modares University, Tehran, 14115-154, Iran. Hauptthemen laut MEDLINE: Silicon Dioxide, Nanoparticles, Aptamers, Nucleotide, Luminescent Measurements. Die Arbeit nennt 52 Literaturangaben. Gefördert von: Tarbiat Modares University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Excessive accumulation of reactive oxygen species disrupts repair mechanisms and causes irreversible damage to lipids, proteins, and DNA. A target-responsive chemiluminescence sensor was developed for the sensitive detection of 8-OxodG, an important biomarker of oxidative DNA damage. RESULTS: In this chemiluminescence sensor, acridinium ester (AE) was loaded into KIT-6 mesoporous silica nanoparticles and capping the pores with an 8-oxodG-specific aptamer. In the presence of 8-oxodG, target-aptamer recognition induced aptamer detachment and AE release. The released AE reacted with H2O2 to generate a concentration-dependent chemiluminescence signal. Under optimized conditions, the sensor exhibited a response range of 0.01-100 μM and a detection limit of 4.8 nM in PBS, by achieving a satisfactory recovery rate of 70.4-108.9% with RSD of 12.7-20.0%. The sensor also showed good selectivity and was successfully evaluated in spiked artificial urine with detection limit of 22.03 nM. SIGNIFICANCE: The combination of aptamer-controlled molecular gating, the interconnected pore structure of KIT-6, and chemiluminescent signal generation provides a sensitive controlled-release platform for 8-oxodG detection and supports its further development for biological-sample analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Silicon DioxideNanoparticlesAptamers, NucleotideLuminescent MeasurementsBiosensing TechniquesDeoxyguanosine8-Hydroxy-2'-DeoxyguanosinePorosityLimit of DetectionHumans

Stichwörter der Autor:innen

8-oxodGAptamerBiosensorChemiluminescenceKIT-6Mesoporous silica nanoparticles

Substanzen

Silicon DioxideAptamers, Nucleotide8-Hydroxy-2'-DeoxyguanosineDeoxyguanosine

Autor:innen und Institutionen

  • Department of Biophysics, Faculty of Biological Science, Tarbiat Modares University, Tehran, 14115-154, Iran.
  • Department of Biomaterial, Faculty of Interdisciplinary Sciences and Technologies, Tarbiat Modares University, Tehran, 14115-154, Iran. Electronic address: zahra.vaezi@modares.ac.ir.
  • Department of Biophysics, Faculty of Biological Science, Tarbiat Modares University, Tehran, 14115-154, Iran. Electronic address: naderman@modares.ac.ir.

Förderung

  • Tarbiat Modares University

Zitieren

APA

Imani, M., Vaezi, Z., & Naderi-Manesh, H. (2026). A KIT-6 mesoporous silica nanoparticle-based chemiluminescent aptasensor for sensitive detection of 8-Oxo-dG. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2026.346279

Vancouver

Imani M, Vaezi Z, Naderi-Manesh H. A KIT-6 mesoporous silica nanoparticle-based chemiluminescent aptasensor for sensitive detection of 8-Oxo-dG. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2026.346279

BibTeX
@article{Imani2026,
  author = {Imani, Maryam and Vaezi, Zahra and Naderi-Manesh, Hossein},
  title = {A KIT-6 mesoporous silica nanoparticle-based chemiluminescent aptasensor for sensitive detection of 8-Oxo-dG},
  journal = {Analytica Chimica Acta},
  year = {2026},
  doi = {10.1016/j.aca.2026.346279}
}
Kostenlos starten →