EUVIMEDEUVIMED entdecken
Crossref

An innovative biosensor utilizing aptamer-gated mesoporous silica nanoparticles for determination of aminoglycoside antibiotics through indirect-lateral flow

Reza Ghaffari, Reza Moradi, NoorMohammad Danesh, Mohammad Ramezani, Mona Alibolandi, Khalil Abnous, Seyed Mohammad Taghdisi

Analytica Chimica Acta · 2025

DOI: 10.1016/j.aca.2024.343413 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025. Verfasst von Reza Ghaffari und 6 weiteren Autor:innen. Beteiligte Einrichtung: Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Pha…. Hauptthemen laut MEDLINE: Silicon Dioxide, Aptamers, Nucleotide, Anti-Bacterial Agents, Biosensing Techniques. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: Mashhad University of Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Aminoglycoside antibiotics (AGs) are commonly utilized in both human and veterinary medicine to treat and manage a range of infections. These antibiotics are recognized for their narrow therapeutic window, with an overdose potentially resulting in severe side effects like kidney and ear damage. Hence, the implementation of a quick, precise, and on-the-spot testing method is crucial in clinical settings. In the present investigation, we designed an innovative indirect lateral flow assay (LFA) utilizing aptamers to detect kanamycin, a type of aminoglycoside antibiotics. We prepared mesoporous silica nanoparticles (MSNs) functionalized with amino groups, loaded them with morphine (MOP), and then sealed them with aminoglycoside aptamers (Apt). The complex of gated-MSNs@Apt was tested using the MOP LFA in the presence or absence of kanamycin antibiotics. RESULTS: The indirect LFA system displayed a single colored line in the test line for positive samples, whereas it exhibited double colored lines in both the control line and test line for negative samples. Our custom-designed LFA biosensors demonstrated two linear ranges, from 10 nM to 350 nM and 500 nM-1500 nM, with a limit of detection (LOD) of 5 nM in serum media under optimized conditions. The introduced indirect LFA biosensor was effectively utilized to detect kanamycin, achieving a satisfactory recovery rate of 92.9-109.9 % with RSD of 1.68-7.73 % in serum samples. SIGNIFICANCE: In general, the created LFA system offers a portable, straightforward, and affordable approach for point-of-care (POC) identification of kanamycin and other AGs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Silicon DioxideAptamers, NucleotideAnti-Bacterial AgentsBiosensing TechniquesNanoparticlesPorosityAminoglycosidesKanamycinHumansLimit of Detection

Stichwörter der Autor:innen

AptamerIndirectKanamycinLateral flow biosensorMesoporous silica nanoparticles

Substanzen

Silicon DioxideAptamers, NucleotideAnti-Bacterial AgentsAminoglycosidesKanamycin

Autor:innen und Institutionen

  • Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Pharmaceutical Biotechnology, School of Pharmacy, Mashhad University of M…
  • Department of Pharmaceutical Nanotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Medicinal Chemistry, School of Pharmacy, Mashhad University of Medical Sciences,…
  • Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran.

Förderung

  • Mashhad University of Medical Sciences

Zitieren

APA

Ghaffari, R., Moradi, R., Danesh, N., Ramezani, M., Alibolandi, M., Abnous, K., & Taghdisi, S. M. (2025). An innovative biosensor utilizing aptamer-gated mesoporous silica nanoparticles for determination of aminoglycoside antibiotics through indirect-lateral flow. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.343413

Vancouver

Ghaffari R, Moradi R, Danesh N, Ramezani M, Alibolandi M, Abnous K, et al. An innovative biosensor utilizing aptamer-gated mesoporous silica nanoparticles for determination of aminoglycoside antibiotics through indirect-lateral flow. Analytica Chimica Acta. 2025. doi:10.1016/j.aca.2024.343413

BibTeX
@article{Ghaffari2025,
  author = {Ghaffari, Reza and Moradi, Reza and Danesh, NoorMohammad and Ramezani, Mohammad and Alibolandi, Mona and Abnous, Khalil and Taghdisi, Seyed Mohammad},
  title = {An innovative biosensor utilizing aptamer-gated mesoporous silica nanoparticles for determination of aminoglycoside antibiotics through indirect-lateral flow},
  journal = {Analytica Chimica Acta},
  year = {2025},
  doi = {10.1016/j.aca.2024.343413}
}
Kostenlos starten →