An Efficient Luminol–H 2 O 2 Electrochemiluminescence System with Porous Bimetallic Organic Gels as Signal Booster and Elaborate Heterosequence Aptamer as Recognition Component for Ultrasensitive Biosensing
Analytical Chemistry · 2025
DOI: 10.1021/acs.analchem.5c00980 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Zhe Tang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nephrology, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, People's Republic of Chi…. Hauptthemen laut MEDLINE: Luminol, Aptamers, Nucleotide, Biosensing Techniques, Electrochemical Techniques. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: Natural Science Foundation of Chongqing Municipality, National Natural Science Foundation of China.
Abstract (Originalsprache)
Herein, an efficient luminol-H2O2 electrochemiluminescence (ECL) system with bimetallic organic gels as an ECL signal booster and an innovative heterosequence aptamer recognition as a target conversion strategy is used to construct a sensitive and specific ECL aptasensor for the detection of β2-microglobulin (B2M), a key biomarker for end-stage renal disease (ESRD). Impressively, the porous Fe@Cu bimetallic organic gels (Fe@Cu MOGs) act as coreaction accelerators and confinement-enhanced reactors of the luminol-H2O2 ECL system, amplifying the ECL signal by 21-fold compared to the traditional luminol-H2O2 ECL system, which greatly enhanced the sensitivity of the biosensor. Compared to the homosequence aptamer approach with competitive binding of aptamers to a single site, the heterosequence aptamer approach with synergistic binding to multiple sites could greatly improve the specificity of aptasensor, which is validated by experiments and molecular docking simulations. Therefore, the developed aptasensor exhibits a remarkable dynamic range of 10 fg/mL-1 μg/mL with an ultralow detection limit of 0.9 fg/mL, which is superior to previously reported works. Additionally, the aptasensor demonstrated consistent performance with conventional clinical immunoturbidimetric assays for high B2M concentration detection in 14 clinical samples, as well as exhibiting superior sensitivity for trace B2M levels that are undetectable by immunoturbidimetry. This strategy offers a sensitive and accurate platform for biomarker recognition, with promising applications in trace clinical biomarker detection, disease diagnosis, and therapeutic monitoring, as well as in advancing scientific research on early pathological changes and biomarker discovery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Nephrology, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, People's Republic of China.
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, People's Republic of Ch…
ORCID-Profile: Zhe Tang, Jia-Li Liu, Ruo Yuan
Förderung
- Natural Science Foundation of Chongqing Municipality
- National Natural Science Foundation of China
Zitieren
APA
Tang, Z., Wen, K., Guo, Y., Xie, P., Li, K., Chen, Y., Liu, J. L., Yuan, R., & Peng, K. (2025). An Efficient Luminol–H 2 O 2 Electrochemiluminescence System with Porous Bimetallic Organic Gels as Signal Booster and Elaborate Heterosequence Aptamer as Recognition Component for Ultrasensitive Biosensing. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c00980
Vancouver
Tang Z, Wen K, Guo Y, Xie P, Li K, Chen Y, et al. An Efficient Luminol–H 2 O 2 Electrochemiluminescence System with Porous Bimetallic Organic Gels as Signal Booster and Elaborate Heterosequence Aptamer as Recognition Component for Ultrasensitive Biosensing. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.5c00980
BibTeX
@article{Tang2025,
author = {Tang, Zhe and Wen, Kai and Guo, YuZhuo and Xie, Pan and Li, KeYu and Chen, YiFei and Liu, Jia-Li and Yuan, Ruo and Peng, KanFu},
title = {An Efficient Luminol–H 2 O 2 Electrochemiluminescence System with Porous Bimetallic Organic Gels as Signal Booster and Elaborate Heterosequence Aptamer as Recognition Component for Ultrasensitive Biosensing},
journal = {Analytical Chemistry},
year = {2025},
doi = {10.1021/acs.analchem.5c00980}
}
EUVIMED