EUVIMEDEUVIMED entdecken
Crossref

Nanozyme-loaded colorimetric gelatin methacryloyl microneedles for glucose detection in interstitial fluid

Shixian Lin, Ziqing Mao, Mengyao Miao, Wensheng Lin, Min Hu, Xinyan Shi, Ruxi Jin, Xiaoyu Lv, Ruijie Liang, Shijie Wang, Jingyan Li, Yupeng Xie und 3 weitere

Analytica Chimica Acta · 2026

DOI: 10.1016/j.aca.2026.345861 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Shixian Lin und 14 weiteren Autor:innen. Beteiligte Einrichtung: The Fourth Affiliated Hospital of Guangzhou Medical University, School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong,…. Hauptthemen laut MEDLINE: Gelatin, Colorimetry, Glucose, Needles. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Bureau of Education of Guangzhou Municipality, Guangdong Provincial Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The pursuit of portable glucose monitoring has stimulated growing interest in interstitial fluid (ISF) as an alternative diagnostic medium, due to its strong correlation with blood glucose levels and reduced interference from macromolecular substances. However, the transition toward ISF-based sensing technologies, particularly those employing colorimetric microneedle (MN) patches, has been hindered by the inherent instability of natural enzymes such as horseradish peroxidase (HRP), which undergo significant activity loss under fluctuating environmental conditions. To overcome this critical limitation, we engineered a colorimetric MN patch that leverages the copper oxide nanozymes (CuO NPs) with robust peroxidase-mimicking activity and high stability. The patch was fabricated from a gelatin methacryloyl (GelMA) hydrogel matrix co-embedded with glucose oxidase (GOx) and the chromogenic agent 3,3',5,5'-tetramethylbenzidine (TMB). We demonstrated that within the developed microneedle patch, the nanozyme-enabled system enables glucose level assessment suitable for preliminary screening or trend monitoring across the clinical range of 1.7-21 mmol/L by converting ISF glucose levels into colorimetric signals in mice, with performance showing good agreement with commercial assay kits. The CuO nanozyme-based colorimetric MN patch is easy to operate and requires no professional expertise or large-scale equipment, which suggests potential applicability for future clinical diagnosis and daily monitoring pending additional validation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GelatinColorimetryGlucoseNeedlesExtracellular FluidAnimalsCopperMiceGlucose OxidaseBenzidinesMicroneedle Drug DeliveryMethacrylates

Stichwörter der Autor:innen

CuO nanozymeGelatin methacryloylGlucose detectionInterstitial fluid extractionMicroneedle patch

Substanzen

GelatinGlucoseCopperGlucose Oxidasegelatin methacryloylBenzidines3,3',5,5'-tetramethylbenzidinecupric oxideMethacrylates

Autor:innen und Institutionen

  • The Fourth Affiliated Hospital of Guangzhou Medical University, School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong, China; College of Materials and Energy, Central South University of F…
  • The Fourth Affiliated Hospital of Guangzhou Medical University, School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong, China.
  • Department of Pharmaceutical Sciences, University of Michigan, Ann Arbor, MI, USA. Electronic address: xwzhou@umich.edu.
  • The Fourth Affiliated Hospital of Guangzhou Medical University, School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong, China. Electronic address: zhujixiang@gzhmu.edu.cn.

Förderung

  • Bureau of Education of Guangzhou Municipality
  • Guangdong Provincial Natural Science Foundation

Zitieren

APA

Lin, S., Mao, Z., Miao, M., Lin, W., Hu, M., Shi, X., Jin, R., Lv, X., Liang, R., Wang, S., Li, J., Xie, Y., Yang, F., Zhou, X., & Zhu, J. (2026). Nanozyme-loaded colorimetric gelatin methacryloyl microneedles for glucose detection in interstitial fluid. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2026.345861

Vancouver

Lin S, Mao Z, Miao M, Lin W, Hu M, Shi X, et al. Nanozyme-loaded colorimetric gelatin methacryloyl microneedles for glucose detection in interstitial fluid. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2026.345861

BibTeX
@article{Lin2026,
  author = {Lin, Shixian and Mao, Ziqing and Miao, Mengyao and Lin, Wensheng and Hu, Min and Shi, Xinyan and Jin, Ruxi and Lv, Xiaoyu and Liang, Ruijie and Wang, Shijie and Li, Jingyan and Xie, Yupeng and Yang, Fanwen and Zhou, Xingwu and Zhu, Jixiang},
  title = {Nanozyme-loaded colorimetric gelatin methacryloyl microneedles for glucose detection in interstitial fluid},
  journal = {Analytica Chimica Acta},
  year = {2026},
  doi = {10.1016/j.aca.2026.345861}
}
Kostenlos starten →