Electrochemical platform based on Ti3C2Tx MXene-supported molecularly imprinted polymers for low-level and selective pomalidomide monitoring
Analytica Chimica Acta · 2026-07 · 1405 · 345464
DOI: 10.1016/j.aca.2026.345464 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-07. Verfasst von Cansu Sanli und 8 weiteren Autor:innen. Beteiligte Einrichtung: Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Türkiye; Ankara University, Graduate School of Health Sciences, A…. Hauptthemen laut MEDLINE: Molecularly Imprinted Polymers, Electrochemical Techniques, Thalidomide, Titanium. Die Arbeit nennt 54 Literaturangaben. Gefördert von: Ankara Universitesi, Türkiye Bilimsel ve Teknolojik Araştırma Kurumu.
Abstract (Originalsprache)
BACKGROUND Pomalidomide (POM), a third-generation immunomodulatory drug, is widely used in the therapeutic regimen of multiple myeloma and other hematologic malignancies. Owing to its narrow therapeutic index and substantial interindividual pharmacokinetic variability, accurate quantification of POM in biological matrices is essential to optimize dosing regimens and minimize adverse effects. Conventional analytical systems like HPLC and LC-MS/MS, while highly accurate, can be time-consuming, costly, and technically demanding. RESULTS This study covers the design of a molecularly imprinted polymer (MIP)-based electrochemical sensor incorporating two-dimensional Ti3C2TX MXene nanaolayers (Ti3C2Tx NLs) for sensitive and selective detection and quantification of POM. The sensor's performance was enhanced by the integration of Ti3C2Tx NLs, followed by modifying a GCE via electropolymerization of its surface with 3-thienylboronic acid (3-TBA) as the functional monomer and aniline (ANI) as a co-monomer. Critical parameters, including the template: monomer ratio, the number of polymerization cycles, and the rebinding time, were systematically optimized. EIS, CV, and SEM analyses were used to confirm the formation of selective recognition cavities and the sensor's electrochemical functionality. The developed MIP sensor exhibited excellent linearity across a concentration range of 1.75 × 10-13 M to 1.00 × 10-12 M. It demonstrated outstanding selectivity for POM, even in the presence of structurally similar analogues, co-administered drugs, common biomolecules, and frequently encountered inorganic ions. SIGNIFICANCE AND NOVELTY Overall, this highly sensitive, selective, and cost-effective MIP-based sensor, which demonstrates excellent stability and performance even in complex matrices, provides a robust, practical analytical tool for routine therapeutic drug monitoring of POM in clinical settings. Moreover, the sensor's straightforward fabrication, low operational cost, and reproducible analytical behavior make it a promising alternative to conventional methods, ultimately contributing to more efficient, accessible, and patient-centered therapeutic monitoring platforms.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Türkiye; Ankara University, Graduate School of Health Sciences, Ankara, Türkiye; DEVA Holding A.S., R&D Center, Tekirdag, 59520, Türkiy…
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Türkiye; Ankara University, Graduate School of Health Sciences, Ankara, Türkiye.
- University of Health Sciences, Gülhane Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Türkiye. Electronic address: ahmet.cetinkya@yahoo.com.
- Selçuk University, Faculty of Science, Department of Chemistry, Konya, Türkiye.
- Istanbul Technical University, Faculty of Chemical and Metallurgical Engineering, Department of Metallurgical and Materials Engineering, İstanbul, Türkiye.
- Ankara University, Stem Cell Institute, Ankara, Türkiye.
Förderung
- Ankara Universitesi
- Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Zitieren
APA
Sanli, C., Isa, A., Cetinkaya, A., Gurbuz, H. N., Sorkhe, Y., Unal, M. A., Uzunoglu, A., Atici, E. B., & Ozkan, S. A. (2026). Electrochemical platform based on Ti3C2Tx MXene-supported molecularly imprinted polymers for low-level and selective pomalidomide monitoring. Analytica Chimica Acta, 1405, 345464. https://doi.org/10.1016/j.aca.2026.345464
Vancouver
Sanli C, Isa A, Cetinkaya A, Gurbuz HN, Sorkhe Y, Unal MA, et al. Electrochemical platform based on Ti3C2Tx MXene-supported molecularly imprinted polymers for low-level and selective pomalidomide monitoring. Analytica Chimica Acta. 2026;1405:345464. doi:10.1016/j.aca.2026.345464
BibTeX
@article{Sanli2026,
author = {Sanli, Cansu and Isa, Ahmed and Cetinkaya, Ahmet and Gurbuz, Havva Nur and Sorkhe, Yahya and Unal, M Altay and Uzunoglu, Aytekin and Atici, Esen Bellur and Ozkan, Sibel A},
title = {Electrochemical platform based on Ti3C2Tx MXene-supported molecularly imprinted polymers for low-level and selective pomalidomide monitoring},
journal = {Analytica Chimica Acta},
year = {2026},
volume = {1405},
pages = {345464},
doi = {10.1016/j.aca.2026.345464}
}
EUVIMED