EUVIMEDEUVIMED entdecken
Crossref

Electrochemical platform based on Ti3C2Tx MXene-supported molecularly imprinted polymers for low-level and selective pomalidomide monitoring

Cansu Sanli, Ahmed Isa, Ahmet Cetinkaya, Havva Nur Gurbuz, Yahya Sorkhe, M Altay Unal, Aytekin Uzunoglu, Esen Bellur Atici, Sibel A Ozkan

Analytica Chimica Acta · 2026-07 · 1405 · 345464

DOI: 10.1016/j.aca.2026.345464 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-07. Verfasst von Cansu Sanli und 8 weiteren Autor:innen. Beteiligte Einrichtung: Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Türkiye; Ankara University, Graduate School of Health Sciences, A…. Hauptthemen laut MEDLINE: Molecularly Imprinted Polymers, Electrochemical Techniques, Thalidomide, Titanium. Die Arbeit nennt 54 Literaturangaben. Gefördert von: Ankara Universitesi, Türkiye Bilimsel ve Teknolojik Araştırma Kurumu.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND Pomalidomide (POM), a third-generation immunomodulatory drug, is widely used in the therapeutic regimen of multiple myeloma and other hematologic malignancies. Owing to its narrow therapeutic index and substantial interindividual pharmacokinetic variability, accurate quantification of POM in biological matrices is essential to optimize dosing regimens and minimize adverse effects. Conventional analytical systems like HPLC and LC-MS/MS, while highly accurate, can be time-consuming, costly, and technically demanding. RESULTS This study covers the design of a molecularly imprinted polymer (MIP)-based electrochemical sensor incorporating two-dimensional Ti3C2TX MXene nanaolayers (Ti3C2Tx NLs) for sensitive and selective detection and quantification of POM. The sensor's performance was enhanced by the integration of Ti3C2Tx NLs, followed by modifying a GCE via electropolymerization of its surface with 3-thienylboronic acid (3-TBA) as the functional monomer and aniline (ANI) as a co-monomer. Critical parameters, including the template: monomer ratio, the number of polymerization cycles, and the rebinding time, were systematically optimized. EIS, CV, and SEM analyses were used to confirm the formation of selective recognition cavities and the sensor's electrochemical functionality. The developed MIP sensor exhibited excellent linearity across a concentration range of 1.75 × 10-13 M to 1.00 × 10-12 M. It demonstrated outstanding selectivity for POM, even in the presence of structurally similar analogues, co-administered drugs, common biomolecules, and frequently encountered inorganic ions. SIGNIFICANCE AND NOVELTY Overall, this highly sensitive, selective, and cost-effective MIP-based sensor, which demonstrates excellent stability and performance even in complex matrices, provides a robust, practical analytical tool for routine therapeutic drug monitoring of POM in clinical settings. Moreover, the sensor's straightforward fabrication, low operational cost, and reproducible analytical behavior make it a promising alternative to conventional methods, ultimately contributing to more efficient, accessible, and patient-centered therapeutic monitoring platforms.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Molecularly Imprinted PolymersElectrochemical TechniquesThalidomideTitaniumMolecular ImprintingLimit of DetectionHumansNitritesTransition Elements

Stichwörter der Autor:innen

Drug analysisElectrochemical sensorsMXene nanomaterialsMolecularly imprinted polymersPomalidomide

Substanzen

Molecularly Imprinted PolymersThalidomidepomalidomideTitaniumMXeneNitritesTransition Elements

Autor:innen und Institutionen

  • Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Türkiye; Ankara University, Graduate School of Health Sciences, Ankara, Türkiye; DEVA Holding A.S., R&D Center, Tekirdag, 59520, Türkiy…
  • Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Türkiye; Ankara University, Graduate School of Health Sciences, Ankara, Türkiye.
  • University of Health Sciences, Gülhane Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Türkiye. Electronic address: ahmet.cetinkya@yahoo.com.
  • Selçuk University, Faculty of Science, Department of Chemistry, Konya, Türkiye.
  • Istanbul Technical University, Faculty of Chemical and Metallurgical Engineering, Department of Metallurgical and Materials Engineering, İstanbul, Türkiye.
  • Ankara University, Stem Cell Institute, Ankara, Türkiye.

Förderung

  • Ankara Universitesi
  • Türkiye Bilimsel ve Teknolojik Araştırma Kurumu

Zitieren

APA

Sanli, C., Isa, A., Cetinkaya, A., Gurbuz, H. N., Sorkhe, Y., Unal, M. A., Uzunoglu, A., Atici, E. B., & Ozkan, S. A. (2026). Electrochemical platform based on Ti3C2Tx MXene-supported molecularly imprinted polymers for low-level and selective pomalidomide monitoring. Analytica Chimica Acta, 1405, 345464. https://doi.org/10.1016/j.aca.2026.345464

Vancouver

Sanli C, Isa A, Cetinkaya A, Gurbuz HN, Sorkhe Y, Unal MA, et al. Electrochemical platform based on Ti3C2Tx MXene-supported molecularly imprinted polymers for low-level and selective pomalidomide monitoring. Analytica Chimica Acta. 2026;1405:345464. doi:10.1016/j.aca.2026.345464

BibTeX
@article{Sanli2026,
  author = {Sanli, Cansu and Isa, Ahmed and Cetinkaya, Ahmet and Gurbuz, Havva Nur and Sorkhe, Yahya and Unal, M Altay and Uzunoglu, Aytekin and Atici, Esen Bellur and Ozkan, Sibel A},
  title = {Electrochemical platform based on Ti3C2Tx MXene-supported molecularly imprinted polymers for low-level and selective pomalidomide monitoring},
  journal = {Analytica Chimica Acta},
  year = {2026},
  volume = {1405},
  pages = {345464},
  doi = {10.1016/j.aca.2026.345464}
}
Kostenlos starten →