A tailored Fe3O4@BC@PDES composite for magnetic solid-phase extraction coupled with ultra-high performance liquid chromatography tandem mass spectrometry to detect four amphetamine-type illegal drugs
Analytica Chimica Acta · 2026
DOI: 10.1016/j.aca.2026.345052 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Shurui Cao und 4 weiteren Autor:innen. Beteiligte Einrichtung: Forensic Identification Center, Southwest University of Political Science and Law, Chongqing, 401120, China; Criminal Investigation Law School, South…. Hauptthemen laut MEDLINE: Solid Phase Extraction, Illicit Drugs, Water Pollutants, Chemical, Amphetamine. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 76 Literaturangaben. Gefördert von: Chongqing Municipal Education Commission.
Abstract (Originalsprache)
BACKGROUND: Wastewater-based epidemiology (WBE) has emerged as a transformative tool for the real-time and unbiased surveillance of community-level illicit drug consumption. The reliability of WBE depends on accurately measuring trace drugs in wastewater. Magnetic solid-phase extraction (MSPE) offers a convenient and efficient sample preparation solution. This study addresses this challenge through the development of a selective magnetic nanomaterial and its integration into an optimized analytical method, thereby enhancing the detection of amphetamine-type stimulants (ATSs) and improving WBE accuracy. RESULTS: A tailored Fe3O4@BC@PDES nanocomposite was designed and acquired from pyrolysis of pomelo peel biomass at 700 °C, and simply modified by Fe3O4 and phenylalanine-based deep eutectic solvent via Density functional theory guidance for simultaneously extracting four amphetamine-type stimulants illegal drugs. The adsorption mechanism is mainly the synergistic effect of multiple hydrogen bonding modes and π-π interactions. Subsequently, the extraction parameters of the MSPE were optimized. A method for determining trace amounts of ATSs in wastewater was established by combining ultra-high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). Methodological validation results indicated negligible matrix effects, a favorable linearity (R2 > 0.999), low method limits of detection (0.73-14.17 ng L-1), qualified recovery (96.4 %∼106.6 %) and good precisions (intra-day and inter-day relative standard deviations
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Forensic Identification Center, Southwest University of Political Science and Law, Chongqing, 401120, China; Criminal Investigation Law School, Southwest University of Political Science Band Law, Chongqing, 401120, Chin…
- College of Pharmacy, Chongqing Medical University, Chongqing, 400016, China.
- Forensic Identification Center, Southwest University of Political Science and Law, Chongqing, 401120, China.
Förderung
- Chongqing Municipal Education Commission
Zitieren
APA
Cao, S., Wei, X., Su, H., Tian, J., & Chen, Z. (2026). A tailored Fe3O4@BC@PDES composite for magnetic solid-phase extraction coupled with ultra-high performance liquid chromatography tandem mass spectrometry to detect four amphetamine-type illegal drugs. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2026.345052
Vancouver
Cao S, Wei X, Su H, Tian J, Chen Z. A tailored Fe3O4@BC@PDES composite for magnetic solid-phase extraction coupled with ultra-high performance liquid chromatography tandem mass spectrometry to detect four amphetamine-type illegal drugs. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2026.345052
BibTeX
@article{Cao2026,
author = {Cao, Shurui and Wei, Xin and Su, Hongtao and Tian, Jie and Chen, Zhiqiong},
title = {A tailored Fe3O4@BC@PDES composite for magnetic solid-phase extraction coupled with ultra-high performance liquid chromatography tandem mass spectrometry to detect four amphetamine-type illegal drugs},
journal = {Analytica Chimica Acta},
year = {2026},
doi = {10.1016/j.aca.2026.345052}
}
EUVIMED