EUVIMEDEUVIMED entdecken
Crossref

Magnetic Molecularly Imprinted Polymers for Extraction of Four Amphetamine‐Type Stimulants From Sewage and Urine

Haocheng Fan, Dongqin Tan, Yue Wang, Yanying Li, Degao Wang

Journal of Separation Science · 2025

DOI: 10.1002/jssc.70197 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Separation Science, 2025. Verfasst von Haocheng Fan und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Environmental Science and Engineering, Dalian Maritime University, Dalian, Liaoning, China. Hauptthemen laut MEDLINE: Molecularly Imprinted Polymers, Sewage, Amphetamines, Amphetamine. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetic molecularly imprinted polymers (MMIPs) were synthesized by bulk polymerization using N‐methylphenethylamine as a dummy template for selective extraction of four amphetamine‐type stimulants (ATSs) in sewage and urine. The MMIPs were characterized by scanning electron microscopy, vibrating sample magnetometer, Fourier transform infrared spectroscopy and thermogravimetric analysis, revealing a porous structure (35–60 µm) with a saturation magnetization of 1.8 emu/g, enabling rapid magnetic separation within 1 min. Adsorption kinetics followed a pseudo‐second‐order model, achieving over 80% adsorption within 10 min and an imprinting factor of 2.4–3.3, demonstrating high selectivity for ATSs over structural analogs. Optimized magnetic solid‐phase extraction (MSPE) conditions yielded recoveries over 81% with relative standard deviation (RSD) below 5.5%. Coupled with high performance liquid chromatography‐tandem mass spectrometry, the proposed MMIPs–MSPE method exhibited a linear range of 1–100 ng/mL, low detection limits (5.2–19 ng/L), and quantification limits (17.0–65.0 ng/L). The pre‐concentration factor of ATSs was 19.3–19.9. Successful application to real sewage and urine samples confirmed robust matrix interference resistance and reliability (recoveries: 82.1%–116%, RSD < 6.4%). This study provides a sensitive, reusable, and environmentally friendly approach for monitoring ATSs in environmental and forensic matrices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Molecularly Imprinted PolymersSewageAmphetaminesAmphetamineSolid Phase ExtractionHumansAdsorptionMolecular ImprintingMagnetic PhenomenaTandem Mass SpectrometryChromatography, High Pressure Liquid

Stichwörter der Autor:innen

amphetaminesmagnetic solid‐phase extractionmolecular imprintingpsychoactive drugwastewater

Substanzen

Molecularly Imprinted PolymersSewageAmphetaminesAmphetamine

Autor:innen und Institutionen

  • College of Environmental Science and Engineering, Dalian Maritime University, Dalian, Liaoning, China.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Fan, H., Tan, D., Wang, Y., Li, Y., & Wang, D. (2025). Magnetic Molecularly Imprinted Polymers for Extraction of Four Amphetamine‐Type Stimulants From Sewage and Urine. Journal of Separation Science. https://doi.org/10.1002/jssc.70197

Vancouver

Fan H, Tan D, Wang Y, Li Y, Wang D. Magnetic Molecularly Imprinted Polymers for Extraction of Four Amphetamine‐Type Stimulants From Sewage and Urine. Journal of Separation Science. 2025. doi:10.1002/jssc.70197

BibTeX
@article{Fan2025,
  author = {Fan, Haocheng and Tan, Dongqin and Wang, Yue and Li, Yanying and Wang, Degao},
  title = {Magnetic Molecularly Imprinted Polymers for Extraction of Four Amphetamine‐Type Stimulants From Sewage and Urine},
  journal = {Journal of Separation Science},
  year = {2025},
  doi = {10.1002/jssc.70197}
}
Kostenlos starten →