EUVIMEDEUVIMED entdecken
Crossref

Development of a miniaturized chemiluminescence lateral flow immunoassay platform with ultra-high sensitivity and ultra-low background for cardiac troponin I

Zixuan Ren, Yue Cui

Analytica Chimica Acta · 2025-10 · 1371 · 344405

DOI: 10.1016/j.aca.2025.344405 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-10. Verfasst von Zixuan Ren und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Engineering Peking University, Beijing 100871, PR China. Hauptthemen laut MEDLINE: Troponin I, Luminescent Measurements. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Peking University, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Lateral flow immunoassays (LFA) are widely used for disease diagnostics due to their simplicity and portability. However, they often suffer from limited sensitivity and accuracy, making them unsuitable for quantitative detection. Additionally, the adsorption and non-specific interactions between label particles and the nitrocellulose membrane may lead to increased background noise, which compromises the repeatability of the device. Therefore, there is an urgent need to develop a highly sensitive, accurate, and high signal-to-noise ratio LFA device that is free from background noise interference. RESULTS: We developed a miniaturized LFA platform that achieves dual-enhanced colorimetric and chemiluminescence signals with ultra-low background noise for detecting cardiac troponin I. The enhancement is achieved through the sequential addition of horseradish peroxidase-streptavidin (HRP-SA) and multiple layers of biotin-antibody (Bio-Ab) conjugated to gold nanoparticles. This conjugation alters the surface charge state of the particles, reducing nonspecific adsorption to the nitrocellulose membrane and significantly lowering background noise. Additionally, the multilayered Bio-Ab coatings and the robust interaction between streptavidin and biotin markedly increase antibody loading, further enhancing the device's sensitivity. A compact smartphone-based imaging setup combined with a high-resolution lens was used for signal readout. The assay strip demonstrated a colorimetric detection range of 100 pg/mL to 10 ng/mL and a chemiluminescent detection range of 10 pg/mL to 10 ng/mL. SIGNIFICANCE: This work establishes a new foundational methodology for chemiluminescence LFA, offering a simpler and more accessible approach that does not require complex equipment, making it ideal for the rapid and on-site diagnosis of acute myocardial infarction. We firmly believe that this method holds great potential for widespread applications in sensitive, and rapid disease diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Troponin ILuminescent MeasurementsImmunoassayHumansLimit of DetectionMiniaturizationGoldStreptavidinSmartphoneMetal NanoparticlesColorimetryHorseradish Peroxidase

Stichwörter der Autor:innen

Background signalCardiac troponin IChemiluminescenceDual-modeLateral flow immunoassaySensitivity

Substanzen

Troponin IGoldStreptavidinHorseradish Peroxidase

Autor:innen und Institutionen

  • School of Materials Science and Engineering Peking University, Beijing 100871, PR China.
  • School of Materials Science and Engineering Peking University, Beijing 100871, PR China. Electronic address: ycui@pku.edu.cn.

Förderung

  • National Key Research and Development Program of China
  • Peking University
  • National Natural Science Foundation of China

Zitieren

APA

Ren, Z., & Cui, Y. (2025). Development of a miniaturized chemiluminescence lateral flow immunoassay platform with ultra-high sensitivity and ultra-low background for cardiac troponin I. Analytica Chimica Acta, 1371, 344405. https://doi.org/10.1016/j.aca.2025.344405

Vancouver

Ren Z, Cui Y. Development of a miniaturized chemiluminescence lateral flow immunoassay platform with ultra-high sensitivity and ultra-low background for cardiac troponin I. Analytica Chimica Acta. 2025;1371:344405. doi:10.1016/j.aca.2025.344405

BibTeX
@article{Ren2025,
  author = {Ren, Zixuan and Cui, Yue},
  title = {Development of a miniaturized chemiluminescence lateral flow immunoassay platform with ultra-high sensitivity and ultra-low background for cardiac troponin I},
  journal = {Analytica Chimica Acta},
  year = {2025},
  volume = {1371},
  pages = {344405},
  doi = {10.1016/j.aca.2025.344405}
}
Kostenlos starten →