EUVIMEDEUVIMED entdecken
Crossref

One-Pot Synthesis of N -(4-Aminobutyl)- N -ethylisoluminol Doping Cuprous Oxide Nanocubes for Label-Free Chemiluminescence Immunoassay of Cardiac Troponin I

Wencan Zhang, Jiangnan Shu, Manli Wang, Keying Zheng, Hua Cui iD

Analytical Chemistry · 17.06.2025 · 97 (23) · 12116-12124

DOI: 10.1021/acs.analchem.5c00462 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 04.06.2025. Verfasst von Wencan Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Precision and Intelligent Chemistry, University of Science and Technology of China, Hefei, Anhui 230026, China. Hauptthemen laut MEDLINE: Troponin I, Copper, Luminol, Luminescent Measurements. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, a novel chemiluminescence (CL)-functionalized nanomaterial, designated as ABEI@Cu2O nanocubes, was synthesized by doping the CL reagent N-(4-aminobutyl)-N-ethylisoluminol (ABEI) into Cu2O nanocubes via a simple one-pot method. The Cu2O nanocubes not only functioned as an effective nanocarrier but also exhibited peroxidase-like activity, promoting the decomposition of H2O2 to enhance CL emission. The incorporation of ABEI into the Cu2O nanocubes resulted in the concentration of the CL reagent within the cubic structures, reducing the spatial distance between the catalyst and ABEI and, thereby, enhancing the CL signal. The robust and stable CL emission of ABEI@Cu2O nanocubes facilitated the development of a label-free CL immunoassay for the detection of cardiac troponin I (cTnI), a biomarker indicative of an acute myocardial infarction. This immunoassay demonstrated a wide linear detection range from 1.0 × 10-13 to 1.0 × 10-8 g/mL and a low detection limit of 3.27 × 10-14 g/mL, surpassing all existing CL immunoassays for cTnI detection. Moreover, the proposed immunoassay demonstrated excellent sensitivity and precision in the quantitative detection of cTnI in serum samples from both healthy individuals and patients. The exceptional sensitivity and flexibility of this immunoassay, supported by the unique properties of the ABEI@Cu2O nanocubes, highlight its significant potential for the detection of various biomarkers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Troponin ICopperLuminolLuminescent MeasurementsNanostructuresImmunoassayHumansLimit of Detection

Substanzen

Troponin ICopperLuminolcuprous oxideN-(4-aminobutyl)-N-ethylisoluminol

Autor:innen und Institutionen

  • Key Laboratory of Precision and Intelligent Chemistry, University of Science and Technology of China, Hefei, Anhui 230026, China.

ORCID-Profile: Hua Cui

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhang, W., Shu, J., Wang, M., Zheng, K., & Cui, H. (2025). One-Pot Synthesis of N -(4-Aminobutyl)- N -ethylisoluminol Doping Cuprous Oxide Nanocubes for Label-Free Chemiluminescence Immunoassay of Cardiac Troponin I. Analytical Chemistry, 97(23), 12116-12124. https://doi.org/10.1021/acs.analchem.5c00462

Vancouver

Zhang W, Shu J, Wang M, Zheng K, Cui H. One-Pot Synthesis of N -(4-Aminobutyl)- N -ethylisoluminol Doping Cuprous Oxide Nanocubes for Label-Free Chemiluminescence Immunoassay of Cardiac Troponin I. Analytical Chemistry. 2025;97(23):12116-12124. doi:10.1021/acs.analchem.5c00462

BibTeX
@article{Zhang2025,
  author = {Zhang, Wencan and Shu, Jiangnan and Wang, Manli and Zheng, Keying and Cui, Hua},
  title = {One-Pot Synthesis of N -(4-Aminobutyl)- N -ethylisoluminol Doping Cuprous Oxide Nanocubes for Label-Free Chemiluminescence Immunoassay of Cardiac Troponin I},
  journal = {Analytical Chemistry},
  year = {2025},
  volume = {97},
  number = {23},
  pages = {12116--12124},
  doi = {10.1021/acs.analchem.5c00462}
}
Kostenlos starten →