EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Ratiometric electrochemical aptasensor with strand displacement for insulin detection in blood samples

Lei Zhou, Ruifeng Zhu, Gabriela Figueroa-Miranda, Marc Neis, Andreas Offenhäusser, Dirk Mayer

Analytica Chimica Acta · 2024

DOI: 10.1016/j.aca.2024.342823 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Lei Zhou und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany; Faculty I, RWTH Aachen Univer…. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Insulin, Electrochemical Techniques, Biosensing Techniques. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 97 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: China Scholarship Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Diabetes patients suffer either from insulin deficiency or resistance with a high risk of severe long-term complications, thus the quantitative assessment of insulin level is highly desired for diabetes surveillance and management. Utilizing insulin-capturing aptamers may facilitate the development of affordable biosensors however, their rigid G-quadruplex structures impair conformational changes of the aptamers and diminish the sensor signals. RESULTS: Here we report on a ratiometric, electrochemical insulin aptasensor which is achieved by hybridization of an insulin-capturing aptamer and a partially complementary ssDNA to break the rigid G-quadruplex structures. To improve the durability of the aptasensor, the capturing aptamer was immobilized on gold electrodes via two dithiol-phosphoramidite functional groups while methoxy-polyethylene glycol thiol was used as a blocking molecule. The exposure of the sensor to insulin-containing solutions induced the dissociation of the hybridized DNA accompanied by a conformational rearrangement of the capturing aptamer back into a G-quadruplex structure. The reliability of sensor readout was improved by the adoption of an AND logic gate utilizing anthraquinone and methylene blue redox probes associated to the aptamer and complementary strand, respectively. Our aptasensor possessed an improved detection limit of 0.15 nM in comparison to aptasensors without strand displacement. SIGNIFICANCE: The sensor was adapted for detection in real blood and is ready for future PoC diagnostics. The capability of monitoring the insulin level in an affordably manner can improve the treatment for an increasing number of patients in developed and developing nations. The utilization of low-cost and versatile aptamer receptors together with the engineering of ratiometric electrochemical signal recording has the potential to considerably advance the current insulin detection technology toward multi-analyte diabetes sensors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aptamers, NucleotideInsulinElectrochemical TechniquesBiosensing TechniquesHumansG-QuadruplexesGoldLimit of DetectionElectrodes

Stichwörter der Autor:innen

Atomic force microscopyBlood testingInsulin detectionMultithiol-immobilizationPolyethylene glycolRatiometric aptasensor

Substanzen

Aptamers, NucleotideInsulinGold

Autor:innen und Institutionen

  • Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany; Faculty I, RWTH Aachen University, Aachen, Germany.
  • Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany.
  • Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany. Electronic address: dirk.mayer@fz-juelich.de.

Förderung

  • China Scholarship Council

Zitieren

APA

Zhou, L., Zhu, R., Figueroa-Miranda, G., Neis, M., Offenhäusser, A., & Mayer, D. (2024). Ratiometric electrochemical aptasensor with strand displacement for insulin detection in blood samples. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.342823

Vancouver

Zhou L, Zhu R, Figueroa-Miranda G, Neis M, Offenhäusser A, Mayer D. Ratiometric electrochemical aptasensor with strand displacement for insulin detection in blood samples. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.342823

BibTeX
@article{Zhou2024,
  author = {Zhou, Lei and Zhu, Ruifeng and Figueroa-Miranda, Gabriela and Neis, Marc and Offenhäusser, Andreas and Mayer, Dirk},
  title = {Ratiometric electrochemical aptasensor with strand displacement for insulin detection in blood samples},
  journal = {Analytica Chimica Acta},
  year = {2024},
  doi = {10.1016/j.aca.2024.342823}
}
Kostenlos starten →