Simplified ratiometric electrochemiluminescence aptasensor for carcinoembryonic antigen detection based on unmodified aptamer using single luminophore and coreactant
Microchimica Acta · 2025
DOI: 10.1007/s00604-025-07358-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Zhen Gao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, People's Republic of China. Hauptthemen laut MEDLINE: Carcinoembryonic Antigen, Aptamers, Nucleotide, Luminescent Measurements, Biosensing Techniques. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Natural Science Foundation of Shandong Province.
Abstract (Originalsprache)
Ratiometric electrochemiluminescence (ECL) aptasensors have garnered significant interest in bioanalysis by simultaneously measuring two distinct emission signals and utilizing their intensity ratio for quantitative output. However, conventional designs face critical limitations. Mandatory aptamer functionalization elevates fabrication complexity and costs. Additionally, dual-luminophore/coreactant systems often suffer from inherent signal mutual interference. To address these issues, we developed a novel ratiometric ECL aptasensing platform employing a single luminophore (luminol) and coreactant (H2O2) for carcinoembryonic antigen (CEA) detection. This simplified system utilized an unmodified aptamer-G-quadruplex (G4)-hemin complex, which played two roles: (1) suppressing cathodic ECL (Ec) through hydroxyl radical consumption; (2) enhancing anodic ECL (Ea) via catalytic acceleration of luminol and H2O2 oxidation. Target-induced CEA-aptamer binding triggered G4-hemin dissociation, generating inversely correlated Ec enhancement and Ea reduction. This dynamic enabled quantitative CEA detection through the Ec/Ea ratio, achieving an ultrabroad linear range (10 fg mL-1-10 ng mL-1) with a detection limit of 0.85 fg mL-1. Notably, the ratiometric signal is independent of H2O2 concentration. This effectively eliminates interference from H2O2 self-decomposition, significantly improving detection reliability. Successful application in human serum analysis validated clinical utility. This work establishes a new strategy for developing robust ratiometric ECL biosensors, potentially expanding their applications in clinical diagnostics and point-of-care testing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, People's Republic of China.
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, People's Republic of China. shanglei@lcu.edu.cn.
Förderung
- Natural Science Foundation of Shandong Province
Zitieren
APA
Gao, Z., Shang, L., Zhang, W., Jia, L. P., Ma, R. N., Li, X. J., & Wang, H. S. (2025). Simplified ratiometric electrochemiluminescence aptasensor for carcinoembryonic antigen detection based on unmodified aptamer using single luminophore and coreactant. Microchimica Acta. https://doi.org/10.1007/s00604-025-07358-9
Vancouver
Gao Z, Shang L, Zhang W, Jia LP, Ma RN, Li XJ, et al. Simplified ratiometric electrochemiluminescence aptasensor for carcinoembryonic antigen detection based on unmodified aptamer using single luminophore and coreactant. Microchimica Acta. 2025. doi:10.1007/s00604-025-07358-9
BibTeX
@article{Gao2025,
author = {Gao, Zhen and Shang, Lei and Zhang, Wei and Jia, Li-Ping and Ma, Rong-Na and Li, Xiao-Jian and Wang, Huai-Sheng},
title = {Simplified ratiometric electrochemiluminescence aptasensor for carcinoembryonic antigen detection based on unmodified aptamer using single luminophore and coreactant},
journal = {Microchimica Acta},
year = {2025},
doi = {10.1007/s00604-025-07358-9}
}
EUVIMED