Materials science of clear aligner therapy: composition, microstructure, and physical properties of thermoplastic and 3D-printed polymer systems: a structured literature review
Digital and Aligner Orthodontics · 2026
DOI: 10.1007/s44525-026-00013-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Digital and Aligner Orthodontics, 2026. Verfasst von Stefan Abela und 3 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
This review summarises current evidence on materials used for clear aligner fabrication, focusing on thermoformed PETG/TPU systems and directly 3D-printed photopolymers, and relates reported material properties to force decay, ageing, surface quality, optical behaviour, and biocompatibility. PubMed/MEDLINE, Scopus, Embase, and the Cochrane Library were reviewed, supplemented by manufacturer data sheets and technical reports when peer-reviewed data were limited. Studies reporting composition, microstructure, mechanical, optical, or thermal properties, surface behaviour, ageing, or biological safety of aligner materials were considered. PETG is optically clear and stiff (1,800–2,200 MPa; Tg 75–81 °C) but shows marked early stress relaxation; one wet 37 °C study reported 62% force decay over 24 h, mainly in the first 8 h. TPU behaviour is formulation-dependent: single-layer TPU may relax similarly to PETG, whereas selected multilayer TPU/copolyester sheets generate lower initial forces with slower decay. Directly 3D-printed, photocurable urethane–acrylate-based aligners remove model-forming and thermoforming steps and may improve geometric control, but their properties depend on print orientation, washing, post-curing, and degree of conversion. Shape-memory photopolymers near oral temperature show partial recovery, but clinical force-decay data over routine wear intervals remain limited. Aligner material behaviour is formulation- and processing-dependent. Broad labels such as PETG, TPU, or printed resin are insufficient unless manufacturing route, thickness, post-processing, and ageing conditions are reported. Standardised force-decay and ageing protocols, followed by comparative clinical studies, are needed before material-specific claims can guide treatment planning.
Zitieren
APA
Abela, S., Castroflorio, T., Migliorati, M., & Terentjev, E. (2026). Materials science of clear aligner therapy: composition, microstructure, and physical properties of thermoplastic and 3D-printed polymer systems: a structured literature review. Digital and Aligner Orthodontics. https://doi.org/10.1007/s44525-026-00013-5
Vancouver
Abela S, Castroflorio T, Migliorati M, Terentjev E. Materials science of clear aligner therapy: composition, microstructure, and physical properties of thermoplastic and 3D-printed polymer systems: a structured literature review. Digital and Aligner Orthodontics. 2026. doi:10.1007/s44525-026-00013-5
BibTeX
@article{Abela2026,
author = {Abela, Stefan and Castroflorio, Tommaso and Migliorati, Marco and Terentjev, Eugene},
title = {Materials science of clear aligner therapy: composition, microstructure, and physical properties of thermoplastic and 3D-printed polymer systems: a structured literature review},
journal = {Digital and Aligner Orthodontics},
year = {2026},
doi = {10.1007/s44525-026-00013-5}
}