A standardized protocol for clear aligner thickness measurement using a 3D-printed auxiliary device
The Angle Orthodontist · 2026-03 · 96 (2) · 156-164
DOI: 10.2319/112724-977.1 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift The Angle Orthodontist, 2026-03. Verfasst von Peiqi Wang und 7 weiteren Autor:innen. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Orthodontic Appliances, Removable, Orthodontic Appliance Design. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objectives
To develop and validate a standardized protocol for clear aligner (CA) thickness measurement using a three-dimensional (3D)-printed auxiliary device to improve measurement reliability. Materials and Methods 24 pairs of digital dental models (D0s) were included and 3D-printed into physical models (P0s), from which CAs were thermoformed using 0.75-mm polymer sheets. Measurement auxiliary devices (MADs) were designed on D0s through measurement point selection, direction determination, electronic gauge mapping, and base shaping, and then 3D-printed. Two operators measured CA thickness (40 points per CA, 48 CAs) using an electronic gauge both directly (direct measurement, D-M) and with MADs (auxiliary measurement, A-M) across three sessions. Measurement precision (repeatability and reproducibility) of D-M and A-M were analyzed using intraclass correlation coefficients (ICCs) and repeated-measures analysis of variance (ANOVA) or Friedman tests. Bland-Altman plots were used to evaluate intersession agreement.
Results
A-M demonstrated superior intersession repeatability with ICC > 0.90 at all points and high intersession agreement with a narrow 95% limit of agreement (LoA) and minimal outliers. Interoperator reproducibility for A-M was also higher, with ICCs above 0.75 at all points, compared to D-M, which showed ICCs below 0.75 at almost all points.
Conclusions
The 3D-printed auxiliary device-based protocol provides a precise and operator-independent method for CA thickness measurement, offering a tool for quality control and providing a foundation for future research on material advancement and design optimization to improve aligner functionality.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Zitieren
APA
Wang, P., Liu, Q., Leng, J., Zhou, X., Li, P., Han, X., Bai, D., & Xue, C. (2026). A standardized protocol for clear aligner thickness measurement using a 3D-printed auxiliary device. The Angle Orthodontist, 96(2), 156-164. https://doi.org/10.2319/112724-977.1
Vancouver
Wang P, Liu Q, Leng J, Zhou X, Li P, Han X, et al. A standardized protocol for clear aligner thickness measurement using a 3D-printed auxiliary device. The Angle Orthodontist. 2026;96(2):156-164. doi:10.2319/112724-977.1
BibTeX
@article{Wang2026,
author = {Wang, Peiqi and Liu, Qingying and Leng, Junyan and Zhou, Xiaoqin and Li, Peilin and Han, Xianglong and Bai, Ding and Xue, Chaoran},
title = {A standardized protocol for clear aligner thickness measurement using a 3D-printed auxiliary device},
journal = {The Angle Orthodontist},
year = {2026},
volume = {96},
number = {2},
pages = {156--164},
doi = {10.2319/112724-977.1}
}