A Dual-Output Physiology-Informed Neural Network Architecture for Continuous Cuffless Blood Pressure Waveform Estimation: A Proof‑of‑Concept
Artery Research · 01.08.2026 · 32 (1)
DOI: 10.1007/s44200-026-00120-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Artery Research, online erschienen am 01.08.2026. Verfasst von Zaineb Aloui und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Université de Sherbrooke, Sherbrooke, QC Canada. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, FQRNT Strategic Cluster INTER.
Abstract (Originalsprache)
This pilot study introduces the first subject‑specific, physiology‑informed neural network approach for accurate estimation of the full blood pressure (BP) waveform. The method builds on a nonlinear autoregressive model with exogenous inputs (NARX), implemented through artificial neural networks trained on subject‑specific electrocardiography (ECG) and photoplethysmography (PPG) signals. Three model configurations are evaluated: (1) a reference NARX model trained on 30 min of data, (2) a reduced‑data NARX model trained on 15 min, and (3) a physiology‑informed model (NARX physio ), also trained on 15 min, which incorporates a personalized four‑parameter BP–PPG sigmoidal layer into the training process through a dual‑output loss function that simultaneously estimates the BP and PPG waveforms. By embedding BP–PPG physiology directly into training, the architecture ensures internal physiological consistency—something not achieved in existing PPG‑based or purely data‑driven machine learning approaches. All three models were assessed on a small ( n = 5), but rich dataset, covering over six hours of activities of daily living. Despite using only half the training duration of the baseline NARX model, the physiology‑informed approach maintains accurate BP estimation. Beyond improved accuracy, the sigmoidal layer provides physiologically interpretable parameters, including estimated arterial‑compliance curve width with an average of 36.5 mmHg and an estimated PPG contact pressure with an average of 59 mmHg in this study, offering insights unavailable in standard neural network models. Together, these preliminary results suggest that the NARX physio model enables effective personalization of cuffless BP waveform estimation with limited training data, highlighting its potential to improve both the reliability and the clinical relevance of continuous cuffless BP monitoring.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, Université de Sherbrooke, Sherbrooke, QC Canada.
- Research Center on Aging, CIUSSS de l'Estrie-CHUS, Sherbrooke, QC Canada.
Förderung
- Natural Sciences and Engineering Research Council of Canada
- FQRNT Strategic Cluster INTER
Zitieren
APA
Aloui, Z., & Landry, C. (2026). A Dual-Output Physiology-Informed Neural Network Architecture for Continuous Cuffless Blood Pressure Waveform Estimation: A Proof‑of‑Concept. Artery Research, 32(1). https://doi.org/10.1007/s44200-026-00120-3
Vancouver
Aloui Z, Landry C. A Dual-Output Physiology-Informed Neural Network Architecture for Continuous Cuffless Blood Pressure Waveform Estimation: A Proof‑of‑Concept. Artery Research. 2026;32(1). doi:10.1007/s44200-026-00120-3
BibTeX
@article{Aloui2026,
author = {Aloui, Zaineb and Landry, Cederick},
title = {A Dual-Output Physiology-Informed Neural Network Architecture for Continuous Cuffless Blood Pressure Waveform Estimation: A Proof‑of‑Concept},
journal = {Artery Research},
year = {2026},
volume = {32},
number = {1},
doi = {10.1007/s44200-026-00120-3}
}
EUVIMED