BP-diff: a conditional diffusion model for cuffless continuous BP waveform estimation using U-Net
Physiological Measurement · 01.10.2024 · 45 (10) · 105006
DOI: 10.1088/1361-6579/ad7fcc ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Measurement, online erschienen am 14.10.2024. Verfasst von Yinsong Liu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of School of Electronic Engineering, Beijing University of Posts and Telecommunication, Beijing 100876, People's Republic of China. Hauptthemen laut MEDLINE: Photoplethysmography, Blood Pressure Determination. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: BUPT Excellent Ph.D. Students Foundation.
Abstract (Originalsprache)
Objective. Continuous monitoring of blood pressure (BP) is crucial for daily healthcare. Although invasive methods provide accurate continuous BP measurements, they are not suitable for routine use. Photoplethysmography (PPG), a non-invasive technique that detects changes in blood volume within the microcirculation using light, shows promise for BP measurement. The primary goal of this study is to develop a novel cuffless method based on PPG for accurately estimating continuous BP. Approach. We introduce BP-Diff, an end-to-end method for cuffless continuous BP waveform estimation utilizing a conditional diffusion probability model combined with a U-Net architecture. This approach takes advantage of the stochastic properties of diffusion models and the strong feature representation capabilities of U-Net. It integrates the continuous BP waveform as the initial status and uses the PPG signal and its derivatives as conditions to guide the training and sampling process. Main results. BP-Diff was evaluated using both uncalibrated and calibrated schemes. The results indicate that, when uncalibrated, BP-Diff can accurately track BP dynamics, including peak and valley positions, as well as timing. After calibration, BP-Diff achieved highly accurate BP estimations. The mean absolute error of the estimated BP waveforms, along with the systolic BP, diastolic BP, and mean arterial pressure from the calibrated BP-Diff model, were 2.99 mmHg, 2.6 mmHg, 1.4 mmHg, and 1.44 mmHg, respectively. Consistency tests, including Bland–Altman analysis and Pearson correlation, confirmed its high reliability compared to reference BP. BP-Diff meets the American Association for Medical Instrumentation standards and has achieved a Grade A from the British Hypertension Society. Significance. This study utilizes PPG signals to develop a novel cuffless continuous BP measurement method, demonstrating superiority over existing approaches. The method is suitable for integration into wearable devices, providing a practical solution for continuous BP monitoring in everyday healthcare.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of School of Electronic Engineering, Beijing University of Posts and Telecommunication, Beijing 100876, People's Republic of China.
- School of Physics and Electronic Information, Anhui Normal University, Wuhu 241003, People's Republic of China.
- School of Intelligence and Digital Engineering, Luoyang Vocational College of Science and Technology, Luoyang 471000, People's Republic of China.
- Chinese Academy of Sciences Aerospace Information Research Institute, Beijing 100094, People's Republic of China.
ORCID-Profile: Yinsong Liu
Förderung
- BUPT Excellent Ph.D. Students Foundation
Zitieren
APA
Liu, Y., Yu, J., & Mou, H. (2024). BP-diff: a conditional diffusion model for cuffless continuous BP waveform estimation using U-Net. Physiological Measurement, 45(10), 105006. https://doi.org/10.1088/1361-6579/ad7fcc
Vancouver
Liu Y, Yu J, Mou H. BP-diff: a conditional diffusion model for cuffless continuous BP waveform estimation using U-Net. Physiological Measurement. 2024;45(10):105006. doi:10.1088/1361-6579/ad7fcc
BibTeX
@article{Liu2024,
author = {Liu, Yinsong and Yu, Junsheng and Mou, Hanlin},
title = {BP-diff: a conditional diffusion model for cuffless continuous BP waveform estimation using U-Net},
journal = {Physiological Measurement},
year = {2024},
volume = {45},
number = {10},
pages = {105006},
doi = {10.1088/1361-6579/ad7fcc}
}
EUVIMED