Electrogenerated chemiluminescence peptide-based biosensing method for cardiac troponin I using peptide-integrating Ru(bpy)3 2+-functionalized gold nanoparticles as nanoprobe

Manman Dong, Min Li, Honglan Qi, Zhejian Li, Qiang Gao, Chengxiao Zhang

Gold Bulletin · 2015

DOI: 10.1007/s13404-015-0156-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Gold Bulletin, 2015. Verfasst von Manman Dong und 5 weiteren Autor:innen. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A sensitive electrogenerated chemiluminescence peptide-based (ECL-PB) biosensing method for the determination of protein was developed by employing peptide-integrating Ru(bpy)3 2+(bpy = 2,2′-bipyridine)-functionalized gold nanoparticles (Ru(bpy)3 2+-AuNPs-peptide) as nanoprobe. Cardiac troponin I (cTnI), a reliable clinical biomarker for the detection of cardiac injury, was chosen as target protein, while a specific binding peptide (CFYSHSFHENWPS) was used as molecular recognition element. AuNPs were firstly functionalized with Ru(bpy)3 2+ through electrostatic interactions between citrate-capped AuNPs and Ru(bpy)3 2+ to form Ru(bpy)3 2+-AuNPs aggregates and then functionalized with peptide through Au-S bounds to form Ru(bpy)3 2+-AuNPs-peptide nanoprobe. AuNPs not only can capture numerous signal-generating molecules, resulting in high ECL intensity but also can capture a significant amount of the peptide, providing poly binding motif. The specific capture peptide was self-assembled on the surface of a gold electrode and then incubated with the target cTnI and Ru(bpy)3 2+-AuNPs-peptide successively. A sandwich-type peptide/cTnI/Ru(bpy)3 2+-AuNPs-peptide conjugate was formed on the surface of the electrode and an ECL signal was obtained in the presence of tri-n-propylamine. The novel biosensing method facilitates the sensitive detection of cTnI in the range from 3.0 × 10−12 g mL−1 to 7.0 × 10−11 g mL−1 with a low detection limit of 0.5 pg mL−1. This work provides a promising strategy for the determination of proteins with simplicity, high sensitivity, and selectivity.

Zitieren

APA

Dong, M., Li, M., Qi, H., Li, Z., Gao, Q., & Zhang, C. (2015). Electrogenerated chemiluminescence peptide-based biosensing method for cardiac troponin I using peptide-integrating Ru(bpy)3 2+-functionalized gold nanoparticles as nanoprobe. Gold Bulletin. https://doi.org/10.1007/s13404-015-0156-2

Vancouver

Dong M, Li M, Qi H, Li Z, Gao Q, Zhang C. Electrogenerated chemiluminescence peptide-based biosensing method for cardiac troponin I using peptide-integrating Ru(bpy)3 2+-functionalized gold nanoparticles as nanoprobe. Gold Bulletin. 2015. doi:10.1007/s13404-015-0156-2

BibTeX
@article{Dong2015,
  author = {Dong, Manman and Li, Min and Qi, Honglan and Li, Zhejian and Gao, Qiang and Zhang, Chengxiao},
  title = {Electrogenerated chemiluminescence peptide-based biosensing method for cardiac troponin I using peptide-integrating Ru(bpy)3 2+-functionalized gold nanoparticles as nanoprobe},
  journal = {Gold Bulletin},
  year = {2015},
  doi = {10.1007/s13404-015-0156-2}
}
Kostenlos starten →