EUVIMEDEUVIMED entdecken
Crossref

Cardiac troponin I biosensing on dipole-electrodes mediated interdigitated-zeolite transducer

Yu Dong, Thangavel Lakshmipriya, Subash C.B. Gopinath, M.K.Md Arshad, Yuan Seng Wu, Yeng Chen

Arabian Journal of Chemistry · 13.05.2026 · 19 · 6802025

DOI: 10.25259/ajc_680_2025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Arabian Journal of Chemistry, online erschienen am 13.05.2026. Verfasst von Yu Dong und 5 weiteren Autor:innen. Die Arbeit nennt 49 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiovascular disease (CVD), also known as heart disease, is a general term used for disorders that affect the blood and heart vessels and are associated with a significant rate of mortality. In general, examinations and immunoassays are performed to identify and predict CVD-related diseases, but these tests are inconvenient, time-consuming, and require a specific instrument. Researchers have focused on quantifying CVD biomarkers as a substitute for conventional methods and have developed various biosensors for diagnosing CVD. In this study, a highly sensitive zeolite–cardiac troponin I (cTnI)-transducing biosensor was developed on an interdigitated electrode (IDE). Silane-modified zeolite was used on the IDE, and then glutaraldehyde (GLU) premixed with anti-cTnI was attached to the IDE through bonding between aldehyde and amine groups. Premixing GLU with the antibody improved antibody attachment on the IDE, and the zeolite-modified IDE attracted a greater amount of GLU premixed with the antibody. This antibody-modified IDE identified cTnI at concentrations as low as 1 fM on a linear regression curve (1 fM to 1 nM) with R 2 = 0.9417 [y = 4.8325x - 7.9957]. In addition, cTnI-spiked serum enhanced the current by increasing the cTnI concentration, and specificity experiments conducted with relevant proteins (NTproBNP, myoglobulin, fibrinogen, c-reactive protein (CRP), and albumin) and nonimmune antibodies did not change the current responses, confirming the selective and specific detection of cTnI. This cTnI immunoassay quantifies cTnI at a lower level than conventional methods and can be used to diagnose CVD-related issues.

Zitieren

APA

Dong, Y., Lakshmipriya, T., Gopinath, S. C., Arshad, M., Wu, Y. S., & Chen, Y. (2026). Cardiac troponin I biosensing on dipole-electrodes mediated interdigitated-zeolite transducer. Arabian Journal of Chemistry, 19, 6802025. https://doi.org/10.25259/ajc_680_2025

Vancouver

Dong Y, Lakshmipriya T, Gopinath SC, Arshad M, Wu YS, Chen Y. Cardiac troponin I biosensing on dipole-electrodes mediated interdigitated-zeolite transducer. Arabian Journal of Chemistry. 2026;19:6802025. doi:10.25259/ajc_680_2025

BibTeX
@article{Dong2026,
  author = {Dong, Yu and Lakshmipriya, Thangavel and Gopinath, Subash C.B. and Arshad, M.K.Md and Wu, Yuan Seng and Chen, Yeng},
  title = {Cardiac troponin I biosensing on dipole-electrodes mediated interdigitated-zeolite transducer},
  journal = {Arabian Journal of Chemistry},
  year = {2026},
  volume = {19},
  pages = {6802025},
  doi = {10.25259/ajc_680_2025}
}
Kostenlos starten →