Development of a prototype Compton camera consisting of high-resolution scintillator detectors
Physical and Engineering Sciences in Medicine · 2025
DOI: 10.1007/s13246-025-01665-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physical and Engineering Sciences in Medicine, 2025. Verfasst von Sen Yang und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Engineering, Xiangtan University, Xiangtan, 411105, China. Hauptthemen laut MEDLINE: Scintillation Counting. Die Arbeit nennt 46 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Shenzhen Science and Technology Program.
Abstract (Originalsprache)
A prototype Compton camera composed of two high resolution scintillator detectors is presented in this work. The scatterer detector consists of a 21 × 21 gadolinium aluminum gallium garnet (GAGG) crystal array with a crystal size of 0.6 × 0.6 × 2 mm3. The absorber detector consists of a 23 × 23 lutetium yttrium orthosilicate (LYSO) crystal array with a crystal size of 1.0 × 1.0 × 20 mm3. A simple back-projection image reconstruction method was developed. The energy of the scatterer detector was accurately calibrated using the 55, 202, 307 keV gamma-rays from the LYSO natural background and the 511 keV gamma-ray from a 22Na point source. The scatterer detector provides a performance with all crystals clearly resolved even at an energy window of 30-120 keV and an average crystal energy resolution of 10.4% at 511 keV. The absorber detector provides a performance with all crystals clearly resolved, an average crystal depth of interaction resolution of ~ 2 mm and an average crystal energy resolution of 19.4% at 511 keV. An average spatial resolution of 2.5 mm was obtained and 9 point sources of 3 mm apart were well resolved at an image plane 7.5 mm from the front of the scatterer detector by using the 511 keV gamma-rays from a 22Na point sources. Furthermore, iterative reconstruction using the maximum-likelihood expectation maximization (MLEM) algorithm achieved a spatial resolution of ~ 1 mm at a plane 7.5 mm from the front of the scatterer detector. Compared with the simple back-projection method, the MLEM reconstruction significantly enhanced the image contrast and effectively suppressed the background artifacts.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, 411105, China.
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China. zheng.liu@siat.ac.cn.
- National Innovation Center for Advanced Medical Devices, Shenzhen, China. zheng.liu@siat.ac.cn.
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
- Shenzhen Science and Technology Program
Zitieren
APA
Yang, S., Zhang, Y., Liu, Y., Li, H., Gan, P., Mungai, S., Shu, P., Kuang, Z., Ren, N., Yang, Y., & Liu, Z. (2025). Development of a prototype Compton camera consisting of high-resolution scintillator detectors. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-025-01665-4
Vancouver
Yang S, Zhang Y, Liu Y, Li H, Gan P, Mungai S, et al. Development of a prototype Compton camera consisting of high-resolution scintillator detectors. Physical and Engineering Sciences in Medicine. 2025. doi:10.1007/s13246-025-01665-4
BibTeX
@article{Yang2025,
author = {Yang, Sen and Zhang, Youchi and Liu, Yingdu and Li, Haonan and Gan, Pengshuo and Mungai, Samuel and Shu, Pengwei and Kuang, Zhonghua and Ren, Ning and Yang, Yongfeng and Liu, Zheng},
title = {Development of a prototype Compton camera consisting of high-resolution scintillator detectors},
journal = {Physical and Engineering Sciences in Medicine},
year = {2025},
doi = {10.1007/s13246-025-01665-4}
}
EUVIMED