Investigating 4D respiratory cone-beam CT imaging for thoracic interventions on robotic C-arm systems: a deformable phantom study

Tess Reynolds iD, Owen Dillon iD, Yiqun Ma iD, Nicholas Hindley iD, J Webster Stayman iD, Magdalena Bazalova-Carter iD

Physical and Engineering Sciences in Medicine · 2024-12 · 47 (4) · 1751-1762

DOI: 10.1007/s13246-024-01491-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physical and Engineering Sciences in Medicine, online erschienen am 24.10.2024. Verfasst von Tess Reynolds und 5 weiteren Autor:innen. Beteiligte Einrichtung: University of Sydney, Sydney, NSW, Australia. tess.reynolds@sydney.edu.au. Hauptthemen laut MEDLINE: Phantoms, Imaging, Cone-Beam Computed Tomography, Four-Dimensional Computed Tomography, Respiration. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, University of Sydney.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Increasingly, interventional thoracic workflows utilize cone-beam CT (CBCT) to improve navigational and diagnostic yield. Here, we investigate the feasibility of implementing free-breathing 4D respiratory CBCT for motion mitigated imaging in patients unable to perform a breath-hold or without suspending mechanical ventilation during thoracic interventions. Circular 4D respiratory CBCT imaging trajectories were implemented on a clinical robotic CBCT system using additional real-time control hardware. The circular trajectories consisted of 1 × 360° circle at 0° tilt with fixed gantry velocities of 2°/s, 10°/s, and 20°/s. The imaging target was an in-house developed anthropomorphic breathing thorax phantom with deformable lungs and 3D-printed imaging targets. The phantom was programmed to reproduce 3 patient-measured breathing traces. Following image acquisition, projections were retrospectively binned into ten respiratory phases and reconstructed using filtered back projection, model-based, and iterative motion compensated algorithms. A conventional circular acquisition on the system of the free-breathing phantom was used as comparator. Edge Response Width (ERW) of the imaging target boundaries and Contrast-to-Noise Ratio (CNR) were used for image quality quantification. All acquisitions across all traces considered displayed visual evidence of motion blurring, and this was reflected in the quantitative measurements. Additionally, all the 4D respiratory acquisitions displayed a lower contrast compared to the conventional acquisitions for all three traces considered. Overall, the current implementation of 4D respiratory CBCT explored in this study with various gantry velocities combined with motion compensated algorithms improved image sharpness for the slower gantry rotations considered (2°/s and 10°/s) compared to conventional acquisitions over a variety of patient traces.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingCone-Beam Computed TomographyFour-Dimensional Computed TomographyRespirationHumansRoboticsThoraxImage Processing, Computer-AssistedAlgorithms

Stichwörter der Autor:innen

4DCBCTCone-beam CTInterventional imagingRespiratory

Autor:innen und Institutionen

  • University of Sydney, Sydney, NSW, Australia. tess.reynolds@sydney.edu.au.
  • University of Sydney, Sydney, NSW, Australia.
  • Johns Hopkins University, Baltimore, MD, USA.
  • University of Victoria, Victoria, BC, Canada.

ORCID-Profile: Tess Reynolds, Owen Dillon, Yiqun Ma, Nicholas Hindley, J Webster Stayman, Magdalena Bazalova-Carter

Förderung

  • NIBIB NIH HHS
  • University of Sydney

Zitieren

APA

Reynolds, T., Dillon, O., Ma, Y., Hindley, N., Stayman, J. W., & Bazalova-Carter, M. (2024). Investigating 4D respiratory cone-beam CT imaging for thoracic interventions on robotic C-arm systems: a deformable phantom study. Physical and Engineering Sciences in Medicine, 47(4), 1751-1762. https://doi.org/10.1007/s13246-024-01491-0

Vancouver

Reynolds T, Dillon O, Ma Y, Hindley N, Stayman JW, Bazalova-Carter M. Investigating 4D respiratory cone-beam CT imaging for thoracic interventions on robotic C-arm systems: a deformable phantom study. Physical and Engineering Sciences in Medicine. 2024;47(4):1751-1762. doi:10.1007/s13246-024-01491-0

BibTeX
@article{Reynolds2024,
  author = {Reynolds, Tess and Dillon, Owen and Ma, Yiqun and Hindley, Nicholas and Stayman, J Webster and Bazalova-Carter, Magdalena},
  title = {Investigating 4D respiratory cone-beam CT imaging for thoracic interventions on robotic C-arm systems: a deformable phantom study},
  journal = {Physical and Engineering Sciences in Medicine},
  year = {2024},
  volume = {47},
  number = {4},
  pages = {1751--1762},
  doi = {10.1007/s13246-024-01491-0}
}
Kostenlos starten →