Stability of radiomic features from positron emission tomography images: a phantom study comparing advanced reconstruction algorithms and ordered subset expectation maximization
Physical and Engineering Sciences in Medicine · 2024
DOI: 10.1007/s13246-024-01416-x ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Physical and Engineering Sciences in Medicine, 2024. Verfasst von Takuro Shiiba und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Molecular Imaging, Clinical and Educational Collaboration Unit, School of Medical Sciences, Fujita Health University, 1-98, Dengakugaku…. Hauptthemen laut MEDLINE: Phantoms, Imaging, Algorithms, Positron-Emission Tomography, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
In this study, we compared the repeatability and reproducibility of radiomic features obtained from positron emission tomography (PET) images according to the reconstruction algorithm used-advanced reconstruction algorithms, such as HYPER iterative (IT), HYPER deep learning reconstruction (DLR), and HYPER deep progressive reconstruction (DPR), or traditional Ordered Subset Expectation Maximization (OSEM)-to understand the potential variations and implications of using advanced reconstruction techniques in PET-based radiomics. We used a heterogeneous phantom with acrylic spherical beads (4- or 8-mm diameter) filled with 18F. PET images were acquired and reconstructed using OSEM, IT, DLR, and DPR. Original and wavelet radiomic features were calculated using SlicerRadiomics. Radiomic feature repeatability was assessed using the Coefficient of Variance (COV) and intraclass correlation coefficient (ICC), and inter-acquisition time reproducibility was assessed using the concordance correlation coefficient (CCC). For the 4- and 8-mm diameter beads phantom, the proportion of radiomic features with a COV 0.8. Advanced reconstruction methods provided enhanced stability of radiomic features compared with OSEM, suggesting their potential for optimal image reconstruction in PET-based radiomics, offering potential benefits in clinical diagnostics and prognostics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Molecular Imaging, Clinical and Educational Collaboration Unit, School of Medical Sciences, Fujita Health University, 1-98, Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan. takuro.shiiba@fuji…
- Department of Radiology, Fujita Health University Hospital, 1-98, Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan.
Zitieren
APA
Shiiba, T., & Watanabe, M. (2024). Stability of radiomic features from positron emission tomography images: a phantom study comparing advanced reconstruction algorithms and ordered subset expectation maximization. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-024-01416-x
Vancouver
Shiiba T, Watanabe M. Stability of radiomic features from positron emission tomography images: a phantom study comparing advanced reconstruction algorithms and ordered subset expectation maximization. Physical and Engineering Sciences in Medicine. 2024. doi:10.1007/s13246-024-01416-x
BibTeX
@article{Shiiba2024,
author = {Shiiba, Takuro and Watanabe, Masanori},
title = {Stability of radiomic features from positron emission tomography images: a phantom study comparing advanced reconstruction algorithms and ordered subset expectation maximization},
journal = {Physical and Engineering Sciences in Medicine},
year = {2024},
doi = {10.1007/s13246-024-01416-x}
}
EUVIMED