On the robustness of [18F]-FDG-PET radiomic features to variations in image acquisition and reconstruction settings: A phantom study
PLOS One · 22.10.2025 · 20 (10) · e0335219
DOI: 10.1371/journal.pone.0335219 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, online erschienen am 22.10.2025. Verfasst von Syafiq Ramlee und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Cambridge, Cambridge, United Kingdom. Hauptthemen laut MEDLINE: Fluorodeoxyglucose F18, Phantoms, Imaging, Positron-Emission Tomography, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIHR Cambridge Biomedical Research Centre, Cancer Research UK Cambridge Centre, "Sultan’s Scholar” scholarship from the Sultan Haji Hassanal Bolkiah Foundation.
Abstract (Originalsprache)
Background
Greater access to clinically meaningful data from [ 18 F]-FDG-PET images could be made possible through radiomics. However, the vulnerability of radiomic measurements to changes in image acquisition and reconstruction settings has raised concerns on their reliability in clinical practice.
Methods
Using the NEMA-IQ phantom, we evaluated the robustness of [ 18 F]-FDG-PET radiomic features to variations in acquisition duration, reconstruction algorithm, transaxial matrix size, z-axis filtering, Gaussian smoothing, and other reconstruction algorithm-specific settings (number of iterations, subsets, updates, and penalisation factors). Feature robustness was assessed using the coefficient of variation (CV < 10%) and intraclass correlation coefficient (ICC > 0.9). Non-robust features were examined for dependencies on these parameters that could be corrected using simple mathematical equations. Using mixed-effects models, we also explored whether differences in region volume or intensity could explain the variability of feature values.
Results
Our findings demonstrated that the majority of [ 18 F]-FDG-PET radiomic features were not robust to variations in image acquisition/reconstruction parameters, with features displaying the least stability to matrix size. Robust features mainly comprised shape-based and entropy-related measurements. Most non-robust features did not possess a dependency on acquisition/reconstruction settings that could be corrected using simple equations. The volume and intensity of interrogated regions were also shown to be likely determinants of feature variability to these settings.
Conclusions
Care should be taken when handling radiomic data extracted from heterogeneously acquired/reconstructed [ 18 F]-FDG-PET images. Alternative strategies could be required to mitigate the effects of variations in these parameters on radiomic features.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Radiology, University of Cambridge, Cambridge, United Kingdom.
- MRC Human Genetics Unit, Institute of Genetics and Cancer, University of Edinburgh, Edinburgh, United Kingdom.
- Cancer Research United Kingdom Cambridge Centre, University of Cambridge, Cambridge, United Kingdom.
- Department of Radiology, Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom.
ORCID-Profile: Syafiq Ramlee, Lorena Escudero Sanchez
Förderung
- NIHR Cambridge Biomedical Research Centre
- Cancer Research UK Cambridge Centre
- "Sultan’s Scholar” scholarship from the Sultan Haji Hassanal Bolkiah Foundation
- W.D. Armstrong Trust Fund
- Cross-disciplinary post-doctoral fellowship from the University of Edinburgh and the Medical Research Council
Zitieren
APA
Ramlee, S., Delgado-Ortet, M., Escudero Sanchez, L., Aloj, L., & Manavaki, R. (2025). On the robustness of [18F]-FDG-PET radiomic features to variations in image acquisition and reconstruction settings: A phantom study. PLOS One, 20(10), e0335219. https://doi.org/10.1371/journal.pone.0335219
Vancouver
Ramlee S, Delgado-Ortet M, Escudero Sanchez L, Aloj L, Manavaki R. On the robustness of [18F]-FDG-PET radiomic features to variations in image acquisition and reconstruction settings: A phantom study. PLOS One. 2025;20(10):e0335219. doi:10.1371/journal.pone.0335219
BibTeX
@article{Ramlee2025,
author = {Ramlee, Syafiq and Delgado-Ortet, Maria and Escudero Sanchez, Lorena and Aloj, Luigi and Manavaki, Roido},
title = {On the robustness of [18F]-FDG-PET radiomic features to variations in image acquisition and reconstruction settings: A phantom study},
journal = {PLOS One},
year = {2025},
volume = {20},
number = {10},
pages = {e0335219},
doi = {10.1371/journal.pone.0335219}
}
EUVIMED