Clinical assessment of cannula performance during adult minimally invasive valve surgery using predictive mathematical models
Interdisciplinary CardioVascular and Thoracic Surgery · 2025
DOI: 10.1093/icvts/ivaf127 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, 2025. Verfasst von Korneel Vandewiele und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Perfusion, Ghent University Hospital, Ghent, Belgium. Hauptthemen laut MEDLINE: Minimally Invasive Surgical Procedures, Cannula, Catheterization, Peripheral, Cardiac Surgical Procedures. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
OBJECTIVES Peripheral cannula selection in minimally invasive cardiac surgery (MICS) is crucial, as venous drainage limitations during cardiopulmonary bypass (CPB) can impair end-organ perfusion and overall outcomes. This study evaluates the in vivo venous drainage efficiency of different peripheral venous cannulas for adult MICS by applying dynamic similarity (DS) prediction formulas. METHODS This observational study included 75 adult MICS patients with use of single peripheral venous cannulation from January 2017 to June 2023. The analysis included cannulas Bio-Medicus Multi XL Life Support, Nextgen Bicaval and Smart cannulas. Cannula performance was assessed by comparing predicted pressures with in vivo measurements. RESULTS A total of 278, 314 and 264 measurements were recorded for the Multi, Next and Smart cannulas, respectively. No significant demographic differences were found between groups. Lin’s concordance correlation coefficients for agreement between predicted and measured pressures were >0.95 for the Multi and Next cannulas but substantially lower for the Smart cannula (0.80). Bland-Altman analysis showed a mean bias of −1.09 mmHg for the Multi, −0.15 mmHg for the Next and 3.68 mmHg for the Smart cannula, with the latter exceeding the ±12.5 mmHg limits of agreement. CONCLUSIONS DS-based predictions revealed significant performance variability among peripheral venous cannula types. The in vivo performance was adequately predicted for the Multi and Next cannulas but not for the Smart cannula, underscoring the need for real-life evaluations and performance monitoring during CPB. Incorporating dynamic performance assessments into clinical decision-making might optimize venous drainage and patient outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Perfusion, Ghent University Hospital, Ghent, Belgium.
- Department of Cardiac Anaesthesia, Ghent University Hospital, Ghent, Belgium.
- Department of Biomedical Engineering, Ghent University, Ghent, Belgium.
- Department of Cardiac Surgery, Ghent University Hospital, Ghent, Belgium.
ORCID-Profile: Korneel Vandewiele
Zitieren
APA
Vandewiele, K., De Somer, F., Vandenheuvel, M., Verdonck, P., & Bové, T. (2025). Clinical assessment of cannula performance during adult minimally invasive valve surgery using predictive mathematical models. Interdisciplinary CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivaf127
Vancouver
Vandewiele K, De Somer F, Vandenheuvel M, Verdonck P, Bové T. Clinical assessment of cannula performance during adult minimally invasive valve surgery using predictive mathematical models. Interdisciplinary CardioVascular and Thoracic Surgery. 2025. doi:10.1093/icvts/ivaf127
BibTeX
@article{Vandewiele2025,
author = {Vandewiele, Korneel and De Somer, Filip and Vandenheuvel, Michael and Verdonck, Pascal and Bové, Thierry},
title = {Clinical assessment of cannula performance during adult minimally invasive valve surgery using predictive mathematical models},
journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
year = {2025},
doi = {10.1093/icvts/ivaf127}
}
EUVIMED