Computer Aided Intracranial Aneurysm Treatment Based on 2D/3D Mapping, Virtual Deployment and Online Distal Marker Detection
Cardiovascular Engineering and Technology · 2024
DOI: 10.1007/s13239-024-00745-y ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Cardiovascular Engineering and Technology, 2024. Verfasst von Nicolas Dazeo und 11 weiteren Autor:innen. Beteiligte Einrichtung: Yatiris Research Group, PLADEMA Institute, CONICET-UNICEN, Campus Universitario, Tandil, Argentina. ndazeo@pladema.exa.unicen.edu.ar. Hauptthemen laut MEDLINE: Intracranial Aneurysm, Imaging, Three-Dimensional, Radiographic Image Interpretation, Computer-Assisted, Endovascular Procedures. Die Arbeit nennt 40 Literaturangaben. Gefördert von: Eurostars.
Abstract (Originalsprache)
PURPOSE: To introduce a computational tool for peri-interventional intracranial aneurysm treatment guidance that maps preoperative planning information from simulation onto real-time X-Ray imaging. METHODS: Preoperatively, multiple flow diverter (FD) devices are simulated based on the 3D mesh of the vessel to treat, to choose the optimal size and location. In the peri-operative stage, this 3D information is aligned and mapped to the continuous 2D-X-Ray scan feed from the operating room. The current flow diverter position in the 3D model is estimated by automatically detecting the distal FD marker locations and mapping them to the treated vessel. This allows to visually assess the possible outcome of releasing the device at the current position, and compare it with the one chosen pre-operatively. RESULTS: The full pipeline was validated using retrospectively collected biplane images from four different patients (5 3D-DSA datasets in total). The distal FD marker detector obtained an average F1-score of 0.67 ( ± 0.224 ) in 412 2D-X-Ray scans. After aligning 3D-DSA + 2D-X-Ray datasets, the average difference between simulated and deployed positions was 0.832 mm ( ± 0.521 mm). Finally, we qualitatively show that the proposed approach is able to display the current location of the FD compared to their pre-operatively planned position. CONCLUSIONS: The proposed method allows to support the FD deployment procedure by merging and presenting preoperative simulation information to the interventionists, aiding them to make more accurate and less risky decisions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Yatiris Research Group, PLADEMA Institute, CONICET-UNICEN, Campus Universitario, Tandil, Argentina. ndazeo@pladema.exa.unicen.edu.ar.
- Yatiris Research Group, PLADEMA Institute, CONICET-UNICEN, Campus Universitario, Tandil, Argentina.
- Mentice S. L., Barcelona, Spain.
- Department of Neuroradiology, Hospital Clinic, Barcelona, Spain.
- Acandis, GmbH, Pforzheim, Germany.
ORCID-Profile: Nicolas Dazeo
Förderung
- Eurostars
Zitieren
APA
Dazeo, N., Orlando, J. I., García, C., Muñoz, R., Obrado, L., Fernandez, H., Blasco, J., Román, L. S., Macho, J. M., Ding, A., Utz, R., & Larrabide, I. (2024). Computer Aided Intracranial Aneurysm Treatment Based on 2D/3D Mapping, Virtual Deployment and Online Distal Marker Detection. Cardiovascular Engineering and Technology. https://doi.org/10.1007/s13239-024-00745-y
Vancouver
Dazeo N, Orlando JI, García C, Muñoz R, Obrado L, Fernandez H, et al. Computer Aided Intracranial Aneurysm Treatment Based on 2D/3D Mapping, Virtual Deployment and Online Distal Marker Detection. Cardiovascular Engineering and Technology. 2024. doi:10.1007/s13239-024-00745-y
BibTeX
@article{Dazeo2024,
author = {Dazeo, Nicolas and Orlando, José Ignacio and García, Camila and Muñoz, Romina and Obrado, Laura and Fernandez, Hector and Blasco, Jordi and Román, Luis San and Macho, Juan M and Ding, Andreas and Utz, Raphael and Larrabide, Ignacio},
title = {Computer Aided Intracranial Aneurysm Treatment Based on 2D/3D Mapping, Virtual Deployment and Online Distal Marker Detection},
journal = {Cardiovascular Engineering and Technology},
year = {2024},
doi = {10.1007/s13239-024-00745-y}
}
EUVIMED